Changes
On December 31, 2024 at 12:31:37 PM +0200, Antti Hildén:
-
Set maintainer of Kampusareena electric vehicle charging consumption and power quality to Antti Hilden (previously Antti Hildén)
f | 1 | { | f | 1 | { |
2 | "author": "", | 2 | "author": "", | ||
3 | "author_email": "", | 3 | "author_email": "", | ||
4 | "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", | 4 | "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", | ||
5 | "data_owner": "University Properties of Finland", | 5 | "data_owner": "University Properties of Finland", | ||
6 | "groups": [ | 6 | "groups": [ | ||
7 | { | 7 | { | ||
8 | "description": "This group collects together data sets related | 8 | "description": "This group collects together data sets related | ||
9 | to the | 9 | to the | ||
10 | ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) | 10 | ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) | ||
11 | building. Kampusareena is a modern office building that provides | 11 | building. Kampusareena is a modern office building that provides | ||
12 | spaces for the personnel of companies, university staff and students, | 12 | spaces for the personnel of companies, university staff and students, | ||
13 | and e.g, for the library of the whole campus. The building was | 13 | and e.g, for the library of the whole campus. The building was | ||
14 | completed in 2015 and is located on the Hervanta campus of Tampere | 14 | completed in 2015 and is located on the Hervanta campus of Tampere | ||
15 | University. Its total area is 16 000 square meters spread out over 8 | 15 | University. Its total area is 16 000 square meters spread out over 8 | ||
16 | floors.\r\n\r\nThe building uses district heating and is cooled with | 16 | floors.\r\n\r\nThe building uses district heating and is cooled with | ||
17 | two cooling machines with the electrical compressor powers of 170 kW | 17 | two cooling machines with the electrical compressor powers of 170 kW | ||
18 | and 226 kW. Ventilation of the building consumes around 100 kW at | 18 | and 226 kW. Ventilation of the building consumes around 100 kW at | ||
19 | maximum. Other electrical loads of the building include two elevators | 19 | maximum. Other electrical loads of the building include two elevators | ||
20 | (max. 7 kW each), eight electric car charging spots (max. 22 kW each) | 20 | (max. 7 kW each), eight electric car charging spots (max. 22 kW each) | ||
21 | and appliances used by tenants (max. 350 kW). Additionally, the | 21 | and appliances used by tenants (max. 350 kW). Additionally, the | ||
22 | building has 57 kW solar power plant. The building is connected to a | 22 | building has 57 kW solar power plant. The building is connected to a | ||
23 | medium voltage distribution network through 20/0.4 kV | 23 | medium voltage distribution network through 20/0.4 kV | ||
24 | transformer.\r\nThe building automation system manages ventilation, | 24 | transformer.\r\nThe building automation system manages ventilation, | ||
25 | heating and cooling of the building. The system involves thousands of | 25 | heating and cooling of the building. The system involves thousands of | ||
26 | data points including indoor conditions of individual spaces, e.g. | 26 | data points including indoor conditions of individual spaces, e.g. | ||
27 | temperature and CO2 concentration, air \ufb02ows and set points for | 27 | temperature and CO2 concentration, air \ufb02ows and set points for | ||
28 | pumps. The electricity consumption of the tenants is measured with | 28 | pumps. The electricity consumption of the tenants is measured with | ||
29 | numerous simple power meters and a couple of more advanced power | 29 | numerous simple power meters and a couple of more advanced power | ||
30 | meters are located at the main distribution boards. Additionally, nine | 30 | meters are located at the main distribution boards. Additionally, nine | ||
31 | power quality meters, called eQL Quality Meters, were installed at the | 31 | power quality meters, called eQL Quality Meters, were installed at the | ||
32 | major loads of the building. These meters offer measured data of | 32 | major loads of the building. These meters offer measured data of | ||
33 | various electrical characteristics even with 100 millisecond time | 33 | various electrical characteristics even with 100 millisecond time | ||
34 | interval.\r\n\r\nMost of the data in this group is owned by University | 34 | interval.\r\n\r\nMost of the data in this group is owned by University | ||
35 | Properties of Finlan (SYK). See the data owner of each dataset to | 35 | Properties of Finlan (SYK). See the data owner of each dataset to | ||
36 | check if that particular data is owned by SYK. Data owned by SYK is | 36 | check if that particular data is owned by SYK. Data owned by SYK is | ||
37 | divided into two categories sensitive (unfiltered) and non sensitive | 37 | divided into two categories sensitive (unfiltered) and non sensitive | ||
38 | (filtered). Sensitive data is related to the tenants of Kampusareena | 38 | (filtered). Sensitive data is related to the tenants of Kampusareena | ||
39 | and is present in the [building automation data | 39 | and is present in the [building automation data | ||
40 | /ckan.energydata.rd.tuni.fi/dataset/kampusareena-building-automation). | 40 | /ckan.energydata.rd.tuni.fi/dataset/kampusareena-building-automation). | ||
41 | In the available measurements list sensitive data is market as | 41 | In the available measurements list sensitive data is market as | ||
42 | confidential. Different conditions apply with sensitive and | 42 | confidential. Different conditions apply with sensitive and | ||
43 | non-sensitive data:\r\n\r\n- Non-sensitive data can be used freely in | 43 | non-sensitive data:\r\n\r\n- Non-sensitive data can be used freely in | ||
44 | research and education use cases. Commercial usage has to be | 44 | research and education use cases. Commercial usage has to be | ||
45 | negotiated with University Properties of Finland.\r\n- sensitive data | 45 | negotiated with University Properties of Finland.\r\n- sensitive data | ||
46 | can be used only by persons designated by the project leader. Data | 46 | can be used only by persons designated by the project leader. Data | ||
47 | handling must be done in accordance with the information security | 47 | handling must be done in accordance with the information security | ||
48 | policies of Tampere University.\r\n", | 48 | policies of Tampere University.\r\n", | ||
49 | "display_name": "Kampusareena", | 49 | "display_name": "Kampusareena", | ||
50 | "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", | 50 | "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", | ||
51 | "image_display_url": "", | 51 | "image_display_url": "", | ||
52 | "name": "kampusareena", | 52 | "name": "kampusareena", | ||
53 | "title": "Kampusareena" | 53 | "title": "Kampusareena" | ||
54 | }, | 54 | }, | ||
55 | { | 55 | { | ||
56 | "description": "This group collects together electrical | 56 | "description": "This group collects together electrical | ||
57 | measurements of the commercial eQL Quality Meter manufactured by | 57 | measurements of the commercial eQL Quality Meter manufactured by | ||
58 | Electrix. The meter comprises advanced power quality features in | 58 | Electrix. The meter comprises advanced power quality features in | ||
59 | addition to energy meter functionalities. The meter has been designed | 59 | addition to energy meter functionalities. The meter has been designed | ||
60 | according to IEC 61000-4-30 Class S. The meter is able collect | 60 | according to IEC 61000-4-30 Class S. The meter is able collect | ||
61 | continuous measurement quantities and event data (voltage dips and | 61 | continuous measurement quantities and event data (voltage dips and | ||
62 | swells, rapid voltage changes, disturbance recordings and | 62 | swells, rapid voltage changes, disturbance recordings and | ||
63 | interruptions). A general list of continuous measurement quantities of | 63 | interruptions). A general list of continuous measurement quantities of | ||
64 | the meter is found below. Dataset specific measurement quantity lists | 64 | the meter is found below. Dataset specific measurement quantity lists | ||
65 | may not include all of these measurement quantities.\r\n\r\n* | 65 | may not include all of these measurement quantities.\r\n\r\n* | ||
66 | fundamental frequency\r\n* voltage\r\n* current\r\n* active power\r\n* | 66 | fundamental frequency\r\n* voltage\r\n* current\r\n* active power\r\n* | ||
67 | fundamental frequency reactive power\r\n* apparent power\r\n* Fryze's | 67 | fundamental frequency reactive power\r\n* apparent power\r\n* Fryze's | ||
68 | reactive power (nonactive power)\r\n* energy\r\n* total distortion of | 68 | reactive power (nonactive power)\r\n* energy\r\n* total distortion of | ||
69 | voltage\r\n* total distortion of current\r\n* harmonic voltage | 69 | voltage\r\n* total distortion of current\r\n* harmonic voltage | ||
70 | (1st-40th order)\r\n* harmonic current (1st-40th order)\r\n* negative | 70 | (1st-40th order)\r\n* harmonic current (1st-40th order)\r\n* negative | ||
71 | sequence component of voltage\r\n* zero sequence component of | 71 | sequence component of voltage\r\n* zero sequence component of | ||
72 | voltage\r\n* DC voltage\r\n* DC current\r\n* power factor\r\n* | 72 | voltage\r\n* DC voltage\r\n* DC current\r\n* power factor\r\n* | ||
73 | displacement power factor\r\n* flicker\r\n* under and over deviation | 73 | displacement power factor\r\n* flicker\r\n* under and over deviation | ||
74 | of voltage\r\n* minimum and maximum of voltage\r\n* minimum and | 74 | of voltage\r\n* minimum and maximum of voltage\r\n* minimum and | ||
75 | maximum of current", | 75 | maximum of current", | ||
76 | "display_name": "eQL quality meter", | 76 | "display_name": "eQL quality meter", | ||
77 | "id": "e5df8df3-49ae-46b5-8e0c-1fda29b64896", | 77 | "id": "e5df8df3-49ae-46b5-8e0c-1fda29b64896", | ||
78 | "image_display_url": "", | 78 | "image_display_url": "", | ||
79 | "name": "eql-quality-meter", | 79 | "name": "eql-quality-meter", | ||
80 | "title": "eQL quality meter" | 80 | "title": "eQL quality meter" | ||
81 | } | 81 | } | ||
82 | ], | 82 | ], | ||
83 | "id": "5284834e-3082-434f-b692-da8b0bafd95b", | 83 | "id": "5284834e-3082-434f-b692-da8b0bafd95b", | ||
84 | "isopen": false, | 84 | "isopen": false, | ||
85 | "license_id": "internal", | 85 | "license_id": "internal", | ||
86 | "license_title": "For internal research and education use", | 86 | "license_title": "For internal research and education use", | ||
n | 87 | "maintainer": "Antti Hild\u00e9n", | n | 87 | "maintainer": "Antti Hilden", |
88 | "maintainer_email": "antti.t.hilden@tuni.fi", | 88 | "maintainer_email": "antti.t.hilden@tuni.fi", | ||
89 | "metadata_created": "2022-12-16T13:36:08.572684", | 89 | "metadata_created": "2022-12-16T13:36:08.572684", | ||
t | 90 | "metadata_modified": "2024-12-31T10:30:47.257574", | t | 90 | "metadata_modified": "2024-12-31T10:31:37.721748", |
91 | "name": | 91 | "name": | ||
92 | kampusareena-electric-vehicle-charging-power-consumption-and-quality", | 92 | kampusareena-electric-vehicle-charging-power-consumption-and-quality", | ||
93 | "notes": "Electrical measurement data of electric vehicle charging | 93 | "notes": "Electrical measurement data of electric vehicle charging | ||
94 | in the Kampusareena building in Tampere. The electric vehicle charging | 94 | in the Kampusareena building in Tampere. The electric vehicle charging | ||
95 | has eight AC charging spots with maximum power of 22.1 kW (type 2 + | 95 | has eight AC charging spots with maximum power of 22.1 kW (type 2 + | ||
96 | schuko) per spot. The charging station is in public use.\r\n\r\nThe | 96 | schuko) per spot. The charging station is in public use.\r\n\r\nThe | ||
97 | data includes 179 continuous timeseries measurement quantities | 97 | data includes 179 continuous timeseries measurement quantities | ||
98 | aggregated at 1-second interval. The measurement quantities consist of | 98 | aggregated at 1-second interval. The measurement quantities consist of | ||
99 | voltage, current, power and energy, and power quality quantities such | 99 | voltage, current, power and energy, and power quality quantities such | ||
100 | as symmetrical components of voltage, and harmonic voltages and | 100 | as symmetrical components of voltage, and harmonic voltages and | ||
101 | currents. The measurement point is at the feeder of the electric | 101 | currents. The measurement point is at the feeder of the electric | ||
102 | vehicle charging at the main distribution board. For details about the | 102 | vehicle charging at the main distribution board. For details about the | ||
103 | measurements see the master's thesis: | 103 | measurements see the master's thesis: | ||
104 | https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nNOTE: Before | 104 | https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nNOTE: Before | ||
105 | 2018-09-06 the meter was installed incorrectly so that positive and | 105 | 2018-09-06 the meter was installed incorrectly so that positive and | ||
106 | negative power amounts where the wrong way around i.e. when power | 106 | negative power amounts where the wrong way around i.e. when power | ||
107 | value is negative in the data it really should be positive.\r\n\r\nSee | 107 | value is negative in the data it really should be positive.\r\n\r\nSee | ||
108 | the | 108 | the | ||
109 | [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) | 109 | [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) | ||
110 | project for general information about how the measurements are stored | 110 | project for general information about how the measurements are stored | ||
111 | and can be used. See the [eQL quality | 111 | and can be used. See the [eQL quality | ||
112 | ter](https://ckan.energydata.rd.tuni.fi/group/about/eql-quality-meter) | 112 | ter](https://ckan.energydata.rd.tuni.fi/group/about/eql-quality-meter) | ||
113 | group for general information about the used measurement device. See | 113 | group for general information about the used measurement device. See | ||
114 | the | 114 | the | ||
115 | usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) | 115 | usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) | ||
116 | group for general information about the building.", | 116 | group for general information about the building.", | ||
117 | "num_resources": 1, | 117 | "num_resources": 1, | ||
118 | "num_tags": 4, | 118 | "num_tags": 4, | ||
119 | "organization": { | 119 | "organization": { | ||
120 | "approval_status": "approved", | 120 | "approval_status": "approved", | ||
121 | "created": "2022-10-14T17:57:03.019118", | 121 | "created": "2022-10-14T17:57:03.019118", | ||
122 | "description": "The ProCem ([Social Energy - Prosumer Centric | 122 | "description": "The ProCem ([Social Energy - Prosumer Centric | ||
123 | Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and | 123 | Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and | ||
124 | ProCemPlus ([Prosumer Centric Energy Communities - towards Energy | 124 | ProCemPlus ([Prosumer Centric Energy Communities - towards Energy | ||
125 | Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have | 125 | Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have | ||
126 | collected energy and energy community related data from the | 126 | collected energy and energy community related data from the | ||
127 | [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) | 127 | [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) | ||
128 | building in the Hervanta campus, the | 128 | building in the Hervanta campus, the | ||
129 | [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) | 129 | [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) | ||
130 | micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data | 130 | micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data | ||
131 | sources.\r\n\r\nThe data for all of the datasets provided by ProCem | 131 | sources.\r\n\r\nThe data for all of the datasets provided by ProCem | ||
132 | have been collected using a custom data collection platform developed | 132 | have been collected using a custom data collection platform developed | ||
133 | as part of the projects. Thus all the data is stored in the same way | 133 | as part of the projects. Thus all the data is stored in the same way | ||
134 | and in the same format and accessing all the data happens in the same | 134 | and in the same format and accessing all the data happens in the same | ||
135 | way. If you are interested in learning more about the data collection | 135 | way. If you are interested in learning more about the data collection | ||
136 | platform, it has been described in a scientific article titled \"[A | 136 | platform, it has been described in a scientific article titled \"[A | ||
137 | Data Collection and Supplementary Control Platform of a Modern | 137 | Data Collection and Supplementary Control Platform of a Modern | ||
138 | Building for Smart Energy | 138 | Building for Smart Energy | ||
139 | ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe | 139 | ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe | ||
140 | data is stored in simple CSV files on a network drive to which select | 140 | data is stored in simple CSV files on a network drive to which select | ||
141 | project researchers have access to. All data from a measurement target | 141 | project researchers have access to. All data from a measurement target | ||
142 | (Kampusareena or Marjam\u00e4ki) for a day are stored in one file. One | 142 | (Kampusareena or Marjam\u00e4ki) for a day are stored in one file. One | ||
143 | line of this CSV file contains these 3 items separated by a tab | 143 | line of this CSV file contains these 3 items separated by a tab | ||
144 | character:\r\n\r\n- **id**: Each measurement point has a unique id | 144 | character:\r\n\r\n- **id**: Each measurement point has a unique id | ||
145 | number. These are documented in the lists of the available | 145 | number. These are documented in the lists of the available | ||
146 | measurements for each dataset.\r\n- **value**: The actual measurement | 146 | measurements for each dataset.\r\n- **value**: The actual measurement | ||
147 | value.\r\n- **timestamp**: Unix time in milliseconds i.e. milliseconds | 147 | value.\r\n- **timestamp**: Unix time in milliseconds i.e. milliseconds | ||
148 | since 1970-01-01 00:00 UTC time.\r\n\r\nIf you want to see a small | 148 | since 1970-01-01 00:00 UTC time.\r\n\r\nIf you want to see a small | ||
149 | example of how these files look like, you can check [this sample | 149 | example of how these files look like, you can check [this sample | ||
150 | ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf | 150 | ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf | ||
151 | you are interested in getting some data from the ProCem datasets, you | 151 | you are interested in getting some data from the ProCem datasets, you | ||
152 | can contact the person marked as the dataset maintainer. Since the raw | 152 | can contact the person marked as the dataset maintainer. Since the raw | ||
153 | data files are very large and contain data sensitive to the data | 153 | data files are very large and contain data sensitive to the data | ||
154 | owner, you will be provided with filtered versions of the data files | 154 | owner, you will be provided with filtered versions of the data files | ||
155 | containing only the data you require from the time period you want. | 155 | containing only the data you require from the time period you want. | ||
156 | So, if you already know precisely what data you want and from what | 156 | So, if you already know precisely what data you want and from what | ||
157 | time period, you can provide the measurement ids of the measurements | 157 | time period, you can provide the measurement ids of the measurements | ||
158 | you want with the range of dates.\r\n\r\nNote, though generally the | 158 | you want with the range of dates.\r\n\r\nNote, though generally the | ||
159 | data collection has been continuous since the date marked as the | 159 | data collection has been continuous since the date marked as the | ||
160 | measurement start date, various issues with measurement devices, | 160 | measurement start date, various issues with measurement devices, | ||
161 | networking or the collection system have caused breaks in data | 161 | networking or the collection system have caused breaks in data | ||
162 | collection varying from minutes to days. So please take this into | 162 | collection varying from minutes to days. So please take this into | ||
163 | account when processing your data.", | 163 | account when processing your data.", | ||
164 | "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | 164 | "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | ||
165 | "image_url": "", | 165 | "image_url": "", | ||
166 | "is_organization": true, | 166 | "is_organization": true, | ||
167 | "name": "procem", | 167 | "name": "procem", | ||
168 | "state": "active", | 168 | "state": "active", | ||
169 | "title": "ProCem", | 169 | "title": "ProCem", | ||
170 | "type": "organization" | 170 | "type": "organization" | ||
171 | }, | 171 | }, | ||
172 | "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | 172 | "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | ||
173 | "private": false, | 173 | "private": false, | ||
174 | "relationships_as_object": [], | 174 | "relationships_as_object": [], | ||
175 | "relationships_as_subject": [], | 175 | "relationships_as_subject": [], | ||
176 | "resources": [ | 176 | "resources": [ | ||
177 | { | 177 | { | ||
178 | "cache_last_updated": null, | 178 | "cache_last_updated": null, | ||
179 | "cache_url": null, | 179 | "cache_url": null, | ||
180 | "created": "2023-02-01T09:40:25.496252", | 180 | "created": "2023-02-01T09:40:25.496252", | ||
181 | "datastore_active": true, | 181 | "datastore_active": true, | ||
182 | "description": "List of available measurements.", | 182 | "description": "List of available measurements.", | ||
183 | "format": "XLSX", | 183 | "format": "XLSX", | ||
184 | "hash": "", | 184 | "hash": "", | ||
185 | "id": "8d8cfbfd-65b2-4085-ae5b-292855f1ee2d", | 185 | "id": "8d8cfbfd-65b2-4085-ae5b-292855f1ee2d", | ||
186 | "last_modified": "2023-02-01T09:40:25.468715", | 186 | "last_modified": "2023-02-01T09:40:25.468715", | ||
187 | "metadata_modified": "2023-02-01T09:40:25.480123", | 187 | "metadata_modified": "2023-02-01T09:40:25.480123", | ||
188 | "mimetype": | 188 | "mimetype": | ||
189 | "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", | 189 | "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", | ||
190 | "mimetype_inner": null, | 190 | "mimetype_inner": null, | ||
191 | "name": | 191 | "name": | ||
192 | "ev_charging_station_power_quality_available_measurements.xlsx", | 192 | "ev_charging_station_power_quality_available_measurements.xlsx", | ||
193 | "package_id": "5284834e-3082-434f-b692-da8b0bafd95b", | 193 | "package_id": "5284834e-3082-434f-b692-da8b0bafd95b", | ||
194 | "position": 0, | 194 | "position": 0, | ||
195 | "resource_type": null, | 195 | "resource_type": null, | ||
196 | "size": 15075, | 196 | "size": 15075, | ||
197 | "state": "active", | 197 | "state": "active", | ||
198 | "url": | 198 | "url": | ||
199 | wnload/ev_charging_station_power_quality_available_measurements.xlsx", | 199 | wnload/ev_charging_station_power_quality_available_measurements.xlsx", | ||
200 | "url_type": "upload" | 200 | "url_type": "upload" | ||
201 | } | 201 | } | ||
202 | ], | 202 | ], | ||
203 | "state": "active", | 203 | "state": "active", | ||
204 | "tags": [ | 204 | "tags": [ | ||
205 | { | 205 | { | ||
206 | "display_name": "Kampusareena", | 206 | "display_name": "Kampusareena", | ||
207 | "id": "509dbd7e-76cf-40b1-801b-d8892486de87", | 207 | "id": "509dbd7e-76cf-40b1-801b-d8892486de87", | ||
208 | "name": "Kampusareena", | 208 | "name": "Kampusareena", | ||
209 | "state": "active", | 209 | "state": "active", | ||
210 | "vocabulary_id": null | 210 | "vocabulary_id": null | ||
211 | }, | 211 | }, | ||
212 | { | 212 | { | ||
213 | "display_name": "electric vehicle charging", | 213 | "display_name": "electric vehicle charging", | ||
214 | "id": "a1ad194a-3d95-4600-918a-9beb95c72a60", | 214 | "id": "a1ad194a-3d95-4600-918a-9beb95c72a60", | ||
215 | "name": "electric vehicle charging", | 215 | "name": "electric vehicle charging", | ||
216 | "state": "active", | 216 | "state": "active", | ||
217 | "vocabulary_id": null | 217 | "vocabulary_id": null | ||
218 | }, | 218 | }, | ||
219 | { | 219 | { | ||
220 | "display_name": "electricity", | 220 | "display_name": "electricity", | ||
221 | "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", | 221 | "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", | ||
222 | "name": "electricity", | 222 | "name": "electricity", | ||
223 | "state": "active", | 223 | "state": "active", | ||
224 | "vocabulary_id": null | 224 | "vocabulary_id": null | ||
225 | }, | 225 | }, | ||
226 | { | 226 | { | ||
227 | "display_name": "power quality", | 227 | "display_name": "power quality", | ||
228 | "id": "f75b4ff7-2ba6-44ba-8468-c1e9c3ba08e4", | 228 | "id": "f75b4ff7-2ba6-44ba-8468-c1e9c3ba08e4", | ||
229 | "name": "power quality", | 229 | "name": "power quality", | ||
230 | "state": "active", | 230 | "state": "active", | ||
231 | "vocabulary_id": null | 231 | "vocabulary_id": null | ||
232 | } | 232 | } | ||
233 | ], | 233 | ], | ||
234 | "temporal_resolution": "1 second", | 234 | "temporal_resolution": "1 second", | ||
235 | "temporal_start": "2018-05-17", | 235 | "temporal_start": "2018-05-17", | ||
236 | "title": "Kampusareena electric vehicle charging consumption and | 236 | "title": "Kampusareena electric vehicle charging consumption and | ||
237 | power quality", | 237 | power quality", | ||
238 | "type": "dataset", | 238 | "type": "dataset", | ||
239 | "url": "", | 239 | "url": "", | ||
240 | "version": "" | 240 | "version": "" | ||
241 | } | 241 | } |