f | { | f | { |
| "author": "", | | "author": "", |
| "author_email": "", | | "author_email": "", |
| "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", | | "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", |
| "data_owner": "University Properties of Finland", | | "data_owner": "University Properties of Finland", |
| "groups": [ | | "groups": [ |
| { | | { |
| "description": "This group collects together datasets related to | | "description": "This group collects together datasets related to |
| the | | the |
| ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) | | ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) |
| building. Kampusareena is a modern office building that provides | | building. Kampusareena is a modern office building that provides |
| spaces for the personnel of companies, university staff and students, | | spaces for the personnel of companies, university staff and students, |
| and e.g, for the library of the whole campus. The building was | | and e.g, for the library of the whole campus. The building was |
| completed in 2015 and is located on the Hervanta campus of Tampere | | completed in 2015 and is located on the Hervanta campus of Tampere |
| University. Its total area is 16 000 square meters spread out over 8 | | University. Its total area is 16 000 square meters spread out over 8 |
| floors.\r\n\r\nThe building uses district heating and is cooled with | | floors.\r\n\r\nThe building uses district heating and is cooled with |
| two cooling machines with the electrical compressor powers of 170 kW | | two cooling machines with the electrical compressor powers of 170 kW |
| and 226 kW. Ventilation of the building consumes around 138 kW at | | and 226 kW. Ventilation of the building consumes around 138 kW at |
| maximum. Other electrical loads of the building include two elevators | | maximum. Other electrical loads of the building include two elevators |
| (max. 7 kW each), eight electric vehicle charging spots (max. 22 kW | | (max. 7 kW each), eight electric vehicle charging spots (max. 22 kW |
| each) and appliances used by tenants (approx. 350 kW at maximum). | | each) and appliances used by tenants (approx. 350 kW at maximum). |
| Additionally, the building has a 57 kW solar power plant. The building | | Additionally, the building has a 57 kW solar power plant. The building |
| is connected to a medium voltage distribution network through 20/0.4 | | is connected to a medium voltage distribution network through 20/0.4 |
| kV transformer.\r\nThe building automation system manages ventilation, | | kV transformer.\r\nThe building automation system manages ventilation, |
| heating and cooling of the building. The system involves thousands of | | heating and cooling of the building. The system involves thousands of |
| data points including indoor conditions of individual spaces, e.g. | | data points including indoor conditions of individual spaces, e.g. |
| temperature and CO2 concentration, air \ufb02ows and set points for | | temperature and CO2 concentration, air \ufb02ows and set points for |
| pumps. The electricity consumption of the tenants is measured with | | pumps. The electricity consumption of the tenants is measured with |
| numerous simple power meters and a couple of more advanced power | | numerous simple power meters and a couple of more advanced power |
| meters are located at the supply sides of two main distribution | | meters are located at the supply sides of two main distribution |
| boards. Additionally, nine power quality meters, called eQL Quality | | boards. Additionally, nine power quality meters, called eQL Quality |
| Meters, were retrofitted at the major loads of the building. The | | Meters, were retrofitted at the major loads of the building. The |
| electrical network and measurements are described in the master's | | electrical network and measurements are described in the master's |
| thesis: https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nMost of the | | thesis: https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nMost of the |
| data in this group is owned by University Properties of Finland (SYK). | | data in this group is owned by University Properties of Finland (SYK). |
| See the data owner of each dataset to check if that particular data is | | See the data owner of each dataset to check if that particular data is |
| owned by SYK. Data owned by SYK is divided into two categories | | owned by SYK. Data owned by SYK is divided into two categories |
| sensitive (unfiltered) and non sensitive (filtered). Sensitive data is | | sensitive (unfiltered) and non sensitive (filtered). Sensitive data is |
| related to the tenants of Kampusareena and is present in the [building | | related to the tenants of Kampusareena and is present in the [building |
| automation data | | automation data |
| /ckan.energydata.rd.tuni.fi/dataset/kampusareena-building-automation). | | /ckan.energydata.rd.tuni.fi/dataset/kampusareena-building-automation). |
| In the available measurements list sensitive data is market as | | In the available measurements list sensitive data is market as |
| confidential. Different conditions apply with sensitive and | | confidential. Different conditions apply with sensitive and |
| non-sensitive data:\r\n\r\n- Non-sensitive data can be used freely in | | non-sensitive data:\r\n\r\n- Non-sensitive data can be used freely in |
| research and education use cases. Commercial usage has to be | | research and education use cases. Commercial usage has to be |
| negotiated with University Properties of Finland.\r\n- Sensitive data | | negotiated with University Properties of Finland.\r\n- Sensitive data |
| can be used only by persons designated by the project leader. Data | | can be used only by persons designated by the project leader. Data |
| handling must be done in accordance with the information security | | handling must be done in accordance with the information security |
| policies of Tampere University.\r\n", | | policies of Tampere University.\r\n", |
| "display_name": "Kampusareena", | | "display_name": "Kampusareena", |
| "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", | | "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", |
| "image_display_url": "", | | "image_display_url": "", |
| "name": "kampusareena", | | "name": "kampusareena", |
| "title": "Kampusareena" | | "title": "Kampusareena" |
| } | | } |
| ], | | ], |
| "id": "0d9776c8-1a38-4f8e-8c97-c001c5831234", | | "id": "0d9776c8-1a38-4f8e-8c97-c001c5831234", |
| "isopen": false, | | "isopen": false, |
| "license_id": "internal", | | "license_id": "internal", |
| "license_title": "For internal research and education use", | | "license_title": "For internal research and education use", |
| "maintainer": "Antti Hilden", | | "maintainer": "Antti Hilden", |
| "maintainer_email": "antti.t.hilden@tuni.fi", | | "maintainer_email": "antti.t.hilden@tuni.fi", |
| "metadata_created": "2022-12-16T15:17:42.445497", | | "metadata_created": "2022-12-16T15:17:42.445497", |
n | "metadata_modified": "2025-01-12T07:43:19.590797", | n | "metadata_modified": "2025-01-12T07:44:41.674683", |
| "name": "kampusareena-power-consumption", | | "name": "kampusareena-power-consumption", |
| "notes": "Electrical measurement data of three power meters located | | "notes": "Electrical measurement data of three power meters located |
| at the main distribution boards of the Kampusareena building. The data | | at the main distribution boards of the Kampusareena building. The data |
| includes continuous timeseries measurement quantities that have been | | includes continuous timeseries measurement quantities that have been |
| collected at 30 second interval from the meters. The measurement | | collected at 30 second interval from the meters. The measurement |
| quantity aggregation intervals of the meters are unknown. The | | quantity aggregation intervals of the meters are unknown. The |
| measurement quantities consist of voltage, current, power and | | measurement quantities consist of voltage, current, power and |
| energy.\r\n\r\nThe power meters are the following:\r\n* Property | | energy.\r\n\r\nThe power meters are the following:\r\n* Property |
| electricity of the building: Measurement point at the supply side of | | electricity of the building: Measurement point at the supply side of |
| the main distribution board. Meter is Schneider PM820. The loads | | the main distribution board. Meter is Schneider PM820. The loads |
| include elevators, ventilation, cooling, and electric vehicle charging | | include elevators, ventilation, cooling, and electric vehicle charging |
t | among others.\r\n* Tenants' electricity of the building: Measurement | t | among others.\r\n\r\n* Tenants' electricity of the building: |
| point at the supply side of the main distribution board. Meter is | | Measurement point at the supply side of the main distribution board. |
| Schneider PM820. Includes power used for common purposes of the | | Meter is Schneider PM820. Includes power used for common purposes of |
| building such as lighting and power sockets.\r\n* 20 kV supply of the | | the building such as lighting and power sockets.\r\n\r\n* 20 kV supply |
| building: Measurement point at 20 kV side of the two transformers that | | of the building: Measurement point at 20 kV side of the two |
| supply the two main distribution boards of property and tenants' | | transformers that supply the two main distribution boards of property |
| electricity. Meter is Schneider PM3255.\r\n\r\nProperty electricity | | and tenants' electricity. Meter is Schneider PM3255.\r\n\r\nProperty |
| has a parallel, retrofitted measurement [Kampusareena building | | electricity has a parallel, retrofitted measurement [Kampusareena |
| property electricity consumption and power | | building property electricity consumption and power |
| pusareena-mains-of-service-electricity-power-consumption-and-quality), | | pusareena-mains-of-service-electricity-power-consumption-and-quality), |
| and tenants' electricity has a parallel, retrofitted measurement | | and tenants' electricity has a parallel, retrofitted measurement |
| [Kampusareena tenants' electricity consumption and power | | [Kampusareena tenants' electricity consumption and power |
| ins-of-tenant-s-electricity-power-consumption-and-quality).\r\n\r\nFor | | ins-of-tenant-s-electricity-power-consumption-and-quality).\r\n\r\nFor |
| details about the measurements see the master's thesis: | | details about the measurements see the master's thesis: |
| https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nNote: No | | https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nNote: No |
| measurements are available between 19th of February 2024 and 23th of | | measurements are available between 19th of February 2024 and 23th of |
| September 2024.\r\n\r\nSee the | | September 2024.\r\n\r\nSee the |
| [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) | | [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) |
| project for general information about how the measurements are stored | | project for general information about how the measurements are stored |
| and how they can be used. See the | | and how they can be used. See the |
| usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) | | usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) |
| group for general information about the building.", | | group for general information about the building.", |
| "num_resources": 1, | | "num_resources": 1, |
| "num_tags": 4, | | "num_tags": 4, |
| "organization": { | | "organization": { |
| "approval_status": "approved", | | "approval_status": "approved", |
| "created": "2022-10-14T17:57:03.019118", | | "created": "2022-10-14T17:57:03.019118", |
| "description": "The ProCem ([Social Energy - Prosumer Centric | | "description": "The ProCem ([Social Energy - Prosumer Centric |
| Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and | | Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and |
| ProCemPlus ([Prosumer Centric Energy Communities - towards Energy | | ProCemPlus ([Prosumer Centric Energy Communities - towards Energy |
| Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have | | Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have |
| collected energy and energy community related data from the | | collected energy and energy community related data from the |
| [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) | | [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) |
| building in the Hervanta campus, the | | building in the Hervanta campus, the |
| [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) | | [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) |
| micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data | | micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data |
| sources.\r\n\r\nThe data for all of the datasets provided by ProCem | | sources.\r\n\r\nThe data for all of the datasets provided by ProCem |
| have been collected using a custom data collection platform developed | | have been collected using a custom data collection platform developed |
| as part of the projects. Thus all the data is stored in the same way | | as part of the projects. Thus all the data is stored in the same way |
| and in the same format and accessing all the data happens in the same | | and in the same format and accessing all the data happens in the same |
| way. If you are interested in learning more about the data collection | | way. If you are interested in learning more about the data collection |
| platform, it has been described in a scientific article titled \"[A | | platform, it has been described in a scientific article titled \"[A |
| Data Collection and Supplementary Control Platform of a Modern | | Data Collection and Supplementary Control Platform of a Modern |
| Building for Smart Energy | | Building for Smart Energy |
| ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe | | ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe |
| data is stored in simple CSV files on a network drive to which select | | data is stored in simple CSV files on a network drive to which select |
| project researchers have access to. All data from a measurement target | | project researchers have access to. All data from a measurement target |
| (Kampusareena or Marjam\u00e4ki) for a day are stored in one file. One | | (Kampusareena or Marjam\u00e4ki) for a day are stored in one file. One |
| line of this CSV file contains these 3 items separated by a tab | | line of this CSV file contains these 3 items separated by a tab |
| character:\r\n\r\n- **id**: Each measurement point has a unique id | | character:\r\n\r\n- **id**: Each measurement point has a unique id |
| number. These are documented in the lists of the available | | number. These are documented in the lists of the available |
| measurements for each dataset.\r\n- **value**: The actual measurement | | measurements for each dataset.\r\n- **value**: The actual measurement |
| value.\r\n- **timestamp**: Unix time in milliseconds i.e. milliseconds | | value.\r\n- **timestamp**: Unix time in milliseconds i.e. milliseconds |
| since 1970-01-01 00:00 UTC time.\r\n\r\nIf you want to see a small | | since 1970-01-01 00:00 UTC time.\r\n\r\nIf you want to see a small |
| example of how these files look like, you can check [this sample | | example of how these files look like, you can check [this sample |
| ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf | | ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf |
| you are interested in getting some data from the ProCem datasets, you | | you are interested in getting some data from the ProCem datasets, you |
| can contact the person marked as the dataset maintainer. Since the raw | | can contact the person marked as the dataset maintainer. Since the raw |
| data files are very large and contain data sensitive to the data | | data files are very large and contain data sensitive to the data |
| owner, you will be provided with filtered versions of the data files | | owner, you will be provided with filtered versions of the data files |
| containing only the data you require from the time period you want. | | containing only the data you require from the time period you want. |
| So, if you already know precisely what data you want and from what | | So, if you already know precisely what data you want and from what |
| time period, you can provide the measurement ids of the measurements | | time period, you can provide the measurement ids of the measurements |
| you want with the range of dates.\r\n\r\nNote, though generally the | | you want with the range of dates.\r\n\r\nNote, though generally the |
| data collection has been continuous since the date marked as the | | data collection has been continuous since the date marked as the |
| measurement start date, various issues with measurement devices, | | measurement start date, various issues with measurement devices, |
| networking or the collection system have caused breaks in data | | networking or the collection system have caused breaks in data |
| collection varying from minutes to days. So please take this into | | collection varying from minutes to days. So please take this into |
| account when processing your data.", | | account when processing your data.", |
| "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | | "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", |
| "image_url": "", | | "image_url": "", |
| "is_organization": true, | | "is_organization": true, |
| "name": "procem", | | "name": "procem", |
| "state": "active", | | "state": "active", |
| "title": "ProCem", | | "title": "ProCem", |
| "type": "organization" | | "type": "organization" |
| }, | | }, |
| "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | | "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", |
| "private": false, | | "private": false, |
| "relationships_as_object": [], | | "relationships_as_object": [], |
| "relationships_as_subject": [], | | "relationships_as_subject": [], |
| "resources": [ | | "resources": [ |
| { | | { |
| "cache_last_updated": null, | | "cache_last_updated": null, |
| "cache_url": null, | | "cache_url": null, |
| "created": "2023-02-03T07:12:24.554580", | | "created": "2023-02-03T07:12:24.554580", |
| "datastore_active": true, | | "datastore_active": true, |
| "description": "List of available measurements.", | | "description": "List of available measurements.", |
| "format": "XLSX", | | "format": "XLSX", |
| "hash": "", | | "hash": "", |
| "id": "9d4b043b-e6ce-4570-80cf-ac44e3e50f17", | | "id": "9d4b043b-e6ce-4570-80cf-ac44e3e50f17", |
| "last_modified": "2023-02-03T07:12:24.528700", | | "last_modified": "2023-02-03T07:12:24.528700", |
| "metadata_modified": "2023-02-03T07:12:24.541813", | | "metadata_modified": "2023-02-03T07:12:24.541813", |
| "mimetype": | | "mimetype": |
| "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", | | "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", |
| "mimetype_inner": null, | | "mimetype_inner": null, |
| "name": | | "name": |
| "kampusareena_power_consumption_available_measurements.xlsx", | | "kampusareena_power_consumption_available_measurements.xlsx", |
| "package_id": "0d9776c8-1a38-4f8e-8c97-c001c5831234", | | "package_id": "0d9776c8-1a38-4f8e-8c97-c001c5831234", |
| "position": 0, | | "position": 0, |
| "resource_type": null, | | "resource_type": null, |
| "size": 19027, | | "size": 19027, |
| "state": "active", | | "state": "active", |
| "url": | | "url": |
| /download/kampusareena_power_consumption_available_measurements.xlsx", | | /download/kampusareena_power_consumption_available_measurements.xlsx", |
| "url_type": "upload" | | "url_type": "upload" |
| } | | } |
| ], | | ], |
| "state": "active", | | "state": "active", |
| "tags": [ | | "tags": [ |
| { | | { |
| "display_name": "Kampusareena", | | "display_name": "Kampusareena", |
| "id": "509dbd7e-76cf-40b1-801b-d8892486de87", | | "id": "509dbd7e-76cf-40b1-801b-d8892486de87", |
| "name": "Kampusareena", | | "name": "Kampusareena", |
| "state": "active", | | "state": "active", |
| "vocabulary_id": null | | "vocabulary_id": null |
| }, | | }, |
| { | | { |
| "display_name": "electricity", | | "display_name": "electricity", |
| "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", | | "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", |
| "name": "electricity", | | "name": "electricity", |
| "state": "active", | | "state": "active", |
| "vocabulary_id": null | | "vocabulary_id": null |
| }, | | }, |
| { | | { |
| "display_name": "main distribution board", | | "display_name": "main distribution board", |
| "id": "7d40c7e7-d235-49ea-a89f-40335e5aa707", | | "id": "7d40c7e7-d235-49ea-a89f-40335e5aa707", |
| "name": "main distribution board", | | "name": "main distribution board", |
| "state": "active", | | "state": "active", |
| "vocabulary_id": null | | "vocabulary_id": null |
| }, | | }, |
| { | | { |
| "display_name": "transformer", | | "display_name": "transformer", |
| "id": "7fe0e78f-7210-4246-ae25-f5f6372d3eb1", | | "id": "7fe0e78f-7210-4246-ae25-f5f6372d3eb1", |
| "name": "transformer", | | "name": "transformer", |
| "state": "active", | | "state": "active", |
| "vocabulary_id": null | | "vocabulary_id": null |
| } | | } |
| ], | | ], |
| "temporal_resolution": "30 seconds", | | "temporal_resolution": "30 seconds", |
| "temporal_start": "2018-06-26", | | "temporal_start": "2018-06-26", |
| "title": "Kampusareena power consumption", | | "title": "Kampusareena power consumption", |
| "type": "dataset", | | "type": "dataset", |
| "url": "", | | "url": "", |
| "version": "" | | "version": "" |
| } | | } |