On March 16, 2023 at 8:26:53 AM +0200, Ville Heikkilä:
-
Changed value of field
data_owner
toUniversity Properties of Finland Ltd
in Kampusareena solar power plant inverters -
Changed value of field
datastore_active
toTrue
in resource inverters_available_measurements.xlsx in Kampusareena solar power plant inverters
f | 1 | { | f | 1 | { |
2 | "author": "", | 2 | "author": "", | ||
3 | "author_email": "", | 3 | "author_email": "", | ||
4 | "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", | 4 | "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", | ||
n | 5 | "data_owner": "University Properties of Finland", | n | 5 | "data_owner": "University Properties of Finland Ltd", |
6 | "groups": [ | 6 | "groups": [ | ||
7 | { | 7 | { | ||
8 | "description": "This group collects together data sets related | 8 | "description": "This group collects together data sets related | ||
9 | to the | 9 | to the | ||
10 | ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) | 10 | ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) | ||
11 | building. Kampusareena is a modern office building that provides | 11 | building. Kampusareena is a modern office building that provides | ||
12 | spaces for the personnel of companies, university staff and students, | 12 | spaces for the personnel of companies, university staff and students, | ||
13 | and e.g, for the library of the whole campus. The building was | 13 | and e.g, for the library of the whole campus. The building was | ||
14 | completed in 2015 and is located on the Hervanta campus of Tampere | 14 | completed in 2015 and is located on the Hervanta campus of Tampere | ||
15 | University. Its total area is 16 000 square meters spread out over 8 | 15 | University. Its total area is 16 000 square meters spread out over 8 | ||
16 | floors.\r\n\r\nThe building uses district heating and is cooled with | 16 | floors.\r\n\r\nThe building uses district heating and is cooled with | ||
17 | two cooling machines with the electrical compressor powers of 170 kW | 17 | two cooling machines with the electrical compressor powers of 170 kW | ||
18 | and 226 kW. Ventilation of the building consumes around 100 kW at | 18 | and 226 kW. Ventilation of the building consumes around 100 kW at | ||
19 | maximum. Other electrical loads of the building include two elevators | 19 | maximum. Other electrical loads of the building include two elevators | ||
20 | (max. 7 kW each), eight electric car charging spots (max. 22 kW each) | 20 | (max. 7 kW each), eight electric car charging spots (max. 22 kW each) | ||
21 | and appliances used by tenants (max. 350 kW). Additionally, the | 21 | and appliances used by tenants (max. 350 kW). Additionally, the | ||
22 | building has 57 kW solar power plant. The building is connected to a | 22 | building has 57 kW solar power plant. The building is connected to a | ||
23 | medium voltage distribution network through 20/0.4 kV | 23 | medium voltage distribution network through 20/0.4 kV | ||
24 | transformer.\r\nThe building automation system manages ventilation, | 24 | transformer.\r\nThe building automation system manages ventilation, | ||
25 | heating and cooling of the building. The system involves thousands of | 25 | heating and cooling of the building. The system involves thousands of | ||
26 | data points including indoor conditions of individual spaces, e.g. | 26 | data points including indoor conditions of individual spaces, e.g. | ||
27 | temperature and CO2 concentration, air \ufb02ows and set points for | 27 | temperature and CO2 concentration, air \ufb02ows and set points for | ||
28 | pumps. The electricity consumption of the tenants is measured with | 28 | pumps. The electricity consumption of the tenants is measured with | ||
29 | numerous simple power meters and a couple of more advanced power | 29 | numerous simple power meters and a couple of more advanced power | ||
30 | meters are located at the main distribution boards. Additionally, nine | 30 | meters are located at the main distribution boards. Additionally, nine | ||
31 | power quality meters, called eQL Quality Meters, were installed at the | 31 | power quality meters, called eQL Quality Meters, were installed at the | ||
32 | major loads of the building. These meters offer measured data of | 32 | major loads of the building. These meters offer measured data of | ||
33 | various electrical characteristics even with 100 millisecond time | 33 | various electrical characteristics even with 100 millisecond time | ||
34 | interval.\r\n\r\nMost of the data in this group is owned by University | 34 | interval.\r\n\r\nMost of the data in this group is owned by University | ||
35 | Properties of Finlan (SYK). See the data owner of each dataset to | 35 | Properties of Finlan (SYK). See the data owner of each dataset to | ||
36 | check if that particular data is owned by SYK. SYK has given | 36 | check if that particular data is owned by SYK. SYK has given | ||
37 | permission to use the data for internal university research and | 37 | permission to use the data for internal university research and | ||
38 | education. So, for example, it cannot be shared with external parties | 38 | education. So, for example, it cannot be shared with external parties | ||
39 | without a separate permission from SYK.", | 39 | without a separate permission from SYK.", | ||
40 | "display_name": "Kampusareena", | 40 | "display_name": "Kampusareena", | ||
41 | "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", | 41 | "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", | ||
42 | "image_display_url": "", | 42 | "image_display_url": "", | ||
43 | "name": "kampusareena", | 43 | "name": "kampusareena", | ||
44 | "title": "Kampusareena" | 44 | "title": "Kampusareena" | ||
45 | } | 45 | } | ||
46 | ], | 46 | ], | ||
47 | "id": "8d25c48e-4d4e-4376-afa5-0d2a7c5eeda6", | 47 | "id": "8d25c48e-4d4e-4376-afa5-0d2a7c5eeda6", | ||
48 | "isopen": false, | 48 | "isopen": false, | ||
49 | "license_id": "internal", | 49 | "license_id": "internal", | ||
50 | "license_title": "For internal research and education use", | 50 | "license_title": "For internal research and education use", | ||
51 | "maintainer": "Antti Hilden", | 51 | "maintainer": "Antti Hilden", | ||
52 | "maintainer_email": "antti.t.hilden@tuni.fi", | 52 | "maintainer_email": "antti.t.hilden@tuni.fi", | ||
53 | "metadata_created": "2022-12-16T15:49:36.456800", | 53 | "metadata_created": "2022-12-16T15:49:36.456800", | ||
n | 54 | "metadata_modified": "2023-02-02T08:33:40.579141", | n | 54 | "metadata_modified": "2023-03-16T06:26:53.000113", |
55 | "name": "kampusareena-solar-power-plant", | 55 | "name": "kampusareena-solar-power-plant", | ||
56 | "notes": "Electrical measurements from the 4 inverters of the solar | 56 | "notes": "Electrical measurements from the 4 inverters of the solar | ||
57 | power plant of Kampusareena. The maximum power production of the solar | 57 | power plant of Kampusareena. The maximum power production of the solar | ||
58 | plant is 57 kW. The power output goes to the top floor ventilation | 58 | plant is 57 kW. The power output goes to the top floor ventilation | ||
59 | machine room. Collected measurements include frequency, current, | 59 | machine room. Collected measurements include frequency, current, | ||
60 | voltage, power and energy.\r\n\r\nThe inverters are the | 60 | voltage, power and energy.\r\n\r\nThe inverters are the | ||
61 | following:\r\n\r\n- For the west wall 1x SMA STP8000TL (8 kW) \r\n- | 61 | following:\r\n\r\n- For the west wall 1x SMA STP8000TL (8 kW) \r\n- | ||
62 | For the southwest wall 1x SMA STP15000TL (15 kW)\r\n- For the | 62 | For the southwest wall 1x SMA STP15000TL (15 kW)\r\n- For the | ||
63 | southeast wall 2x SMA STP17000TL (2 x 17 kW)\r\n\r\nMost of the data | 63 | southeast wall 2x SMA STP17000TL (2 x 17 kW)\r\n\r\nMost of the data | ||
64 | is collected with a one second interval. However there is some static | 64 | is collected with a one second interval. However there is some static | ||
65 | data about the inverters that is fetched only once per day or when | 65 | data about the inverters that is fetched only once per day or when | ||
66 | ever the collector is started. These values are marked as read once in | 66 | ever the collector is started. These values are marked as read once in | ||
67 | the available measurements list.\r\n\r\nNOTE: Data collected before | 67 | the available measurements list.\r\n\r\nNOTE: Data collected before | ||
68 | 2018-08-08 may contain erroneus data in the form of large negative | 68 | 2018-08-08 may contain erroneus data in the form of large negative | ||
69 | numbers like -2147483648. This is because the collection system | 69 | numbers like -2147483648. This is because the collection system | ||
70 | misinterpreted the value signaling that there were no data since the | 70 | misinterpreted the value signaling that there were no data since the | ||
71 | inverter was not operating. This often occurred during night | 71 | inverter was not operating. This often occurred during night | ||
72 | time.\r\n\r\nSee the | 72 | time.\r\n\r\nSee the | ||
73 | [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) | 73 | [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) | ||
74 | project for general information about how the measurements are stored | 74 | project for general information about how the measurements are stored | ||
75 | and can be used. See the | 75 | and can be used. See the | ||
76 | usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) | 76 | usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) | ||
77 | group for general information about the building.", | 77 | group for general information about the building.", | ||
78 | "num_resources": 1, | 78 | "num_resources": 1, | ||
79 | "num_tags": 3, | 79 | "num_tags": 3, | ||
80 | "organization": { | 80 | "organization": { | ||
81 | "approval_status": "approved", | 81 | "approval_status": "approved", | ||
82 | "created": "2022-10-14T17:57:03.019118", | 82 | "created": "2022-10-14T17:57:03.019118", | ||
83 | "description": "The ProCem ([Social Energy - Prosumer Centric | 83 | "description": "The ProCem ([Social Energy - Prosumer Centric | ||
84 | Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and | 84 | Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and | ||
85 | ProCemPlus ([Prosumer Centric Energy Communities - towards Energy | 85 | ProCemPlus ([Prosumer Centric Energy Communities - towards Energy | ||
86 | Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have | 86 | Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have | ||
87 | collected energy and energy community related data from the | 87 | collected energy and energy community related data from the | ||
88 | [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) | 88 | [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) | ||
89 | building in the Hervanta campus, the | 89 | building in the Hervanta campus, the | ||
90 | [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) | 90 | [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) | ||
91 | micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data | 91 | micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data | ||
92 | sources.\r\n\r\nThe data for all of the datasets provided by ProCem | 92 | sources.\r\n\r\nThe data for all of the datasets provided by ProCem | ||
93 | have been collected using a custom data collection platform developed | 93 | have been collected using a custom data collection platform developed | ||
94 | as part of the projects. Thus all the data is stored in the same way | 94 | as part of the projects. Thus all the data is stored in the same way | ||
95 | and in the same format and accessing all the data happens in the same | 95 | and in the same format and accessing all the data happens in the same | ||
96 | way. If you are interested in learning more about the data collection | 96 | way. If you are interested in learning more about the data collection | ||
97 | platform, it has been described in a scientific article titled \"[A | 97 | platform, it has been described in a scientific article titled \"[A | ||
98 | Data Collection and Supplementary Control Platform of a Modern | 98 | Data Collection and Supplementary Control Platform of a Modern | ||
99 | Building for Smart Energy | 99 | Building for Smart Energy | ||
100 | ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe | 100 | ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe | ||
n | 101 | data is stored in simple CSV files on a network drive where select | n | 101 | data is stored in simple CSV files on a network drive to which select |
102 | project researchers have access to. All data from a measurement target | 102 | project researchers have access to. All data from a measurement target | ||
n | 103 | (Kampusarreenao or Marjam\u00e4ki) for a day are stored in one file. | n | 103 | (Kampusareena or Marjam\u00e4ki) for a day are stored in one file. One |
104 | One line of this CSV file contains these 3 items separated by a | 104 | line of this CSV file contains these 3 items separated by a tab | ||
105 | tab:\r\n\r\n- id: Each measurement point has a unique id number. These | 105 | character:\r\n\r\n- **id**: Each measurement point has a unique id | ||
106 | are documented in the list of available measurements for each | 106 | number. These are documented in the lists of the available | ||
107 | dataset.\r\n- value: The actual measurment value.\r\n- timestamp: Unix | 107 | measurements for each dataset.\r\n- **value**: The actual measurement | ||
108 | time in milliseconds i.e. milliseconds since 1970-01-01 00:00 UTC | 108 | value.\r\n- **timestamp**: Unix time in milliseconds i.e. milliseconds | ||
109 | time.\r\n\r\nIf you want to see a small example of how these files | 109 | since 1970-01-01 00:00 UTC time.\r\n\r\nIf you want to see a small | ||
110 | look like, you can check [this sample data dataset | 110 | example of how these files look like, you can check [this sample | ||
111 | ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf | 111 | ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf | ||
112 | you are interested in getting some data from the ProCem datasets, you | 112 | you are interested in getting some data from the ProCem datasets, you | ||
113 | can contact the person marked as the dataset maintainer. Since the raw | 113 | can contact the person marked as the dataset maintainer. Since the raw | ||
114 | data files are very large and contain data sensitive to the data | 114 | data files are very large and contain data sensitive to the data | ||
n | 115 | owner, you will be provided filtered versions of the data files | n | 115 | owner, you will be provided with filtered versions of the data files |
116 | containing only the data you require from the time period you want. So | 116 | containing only the data you require from the time period you want. | ||
117 | if you already know precisely what data you want and from what time | 117 | So, if you already know precisely what data you want and from what | ||
118 | period, you can provide the measurement ids of the measurements you | 118 | time period, you can provide the measurement ids of the measurements | ||
119 | want and a range of dates.\r\n\r\nNote: Though generally the data | 119 | you want with the range of dates.\r\n\r\nNote, though generally the | ||
120 | collection has been continuous since the date marked as measurement | 120 | data collection has been continuous since the date marked as the | ||
121 | start date, various issues with measurement devices, networking or the | 121 | measurement start date, various issues with measurement devices, | ||
122 | collection system have caused breaks in data collection varying from | 122 | networking or the collection system have caused breaks in data | ||
123 | minutes to days. So please take this into account when processing your | 123 | collection varying from minutes to days. So please take this into | ||
124 | data.", | 124 | account when processing your data.", | ||
125 | "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | 125 | "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | ||
126 | "image_url": "", | 126 | "image_url": "", | ||
127 | "is_organization": true, | 127 | "is_organization": true, | ||
128 | "name": "procem", | 128 | "name": "procem", | ||
129 | "state": "active", | 129 | "state": "active", | ||
130 | "title": "ProCem", | 130 | "title": "ProCem", | ||
131 | "type": "organization" | 131 | "type": "organization" | ||
132 | }, | 132 | }, | ||
133 | "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | 133 | "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | ||
134 | "private": false, | 134 | "private": false, | ||
135 | "relationships_as_object": [], | 135 | "relationships_as_object": [], | ||
136 | "relationships_as_subject": [], | 136 | "relationships_as_subject": [], | ||
137 | "resources": [ | 137 | "resources": [ | ||
138 | { | 138 | { | ||
139 | "cache_last_updated": null, | 139 | "cache_last_updated": null, | ||
140 | "cache_url": null, | 140 | "cache_url": null, | ||
141 | "created": "2023-02-02T08:33:40.593182", | 141 | "created": "2023-02-02T08:33:40.593182", | ||
t | 142 | "datastore_active": false, | t | 142 | "datastore_active": true, |
143 | "description": "", | 143 | "description": "", | ||
144 | "format": "XLSX", | 144 | "format": "XLSX", | ||
145 | "hash": "", | 145 | "hash": "", | ||
146 | "id": "d5e5c629-1ca5-41a6-94a0-86272f561a61", | 146 | "id": "d5e5c629-1ca5-41a6-94a0-86272f561a61", | ||
147 | "last_modified": "2023-02-02T08:33:40.573306", | 147 | "last_modified": "2023-02-02T08:33:40.573306", | ||
148 | "metadata_modified": "2023-02-02T08:33:40.582787", | 148 | "metadata_modified": "2023-02-02T08:33:40.582787", | ||
149 | "mimetype": | 149 | "mimetype": | ||
150 | "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", | 150 | "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", | ||
151 | "mimetype_inner": null, | 151 | "mimetype_inner": null, | ||
152 | "name": "inverters_available_measurements.xlsx", | 152 | "name": "inverters_available_measurements.xlsx", | ||
153 | "package_id": "8d25c48e-4d4e-4376-afa5-0d2a7c5eeda6", | 153 | "package_id": "8d25c48e-4d4e-4376-afa5-0d2a7c5eeda6", | ||
154 | "position": 0, | 154 | "position": 0, | ||
155 | "resource_type": null, | 155 | "resource_type": null, | ||
156 | "size": 17306, | 156 | "size": 17306, | ||
157 | "state": "active", | 157 | "state": "active", | ||
158 | "url": | 158 | "url": | ||
159 | 1a6-94a0-86272f561a61/download/inverters_available_measurements.xlsx", | 159 | 1a6-94a0-86272f561a61/download/inverters_available_measurements.xlsx", | ||
160 | "url_type": "upload" | 160 | "url_type": "upload" | ||
161 | } | 161 | } | ||
162 | ], | 162 | ], | ||
163 | "state": "active", | 163 | "state": "active", | ||
164 | "tags": [ | 164 | "tags": [ | ||
165 | { | 165 | { | ||
166 | "display_name": "Kampusareena", | 166 | "display_name": "Kampusareena", | ||
167 | "id": "509dbd7e-76cf-40b1-801b-d8892486de87", | 167 | "id": "509dbd7e-76cf-40b1-801b-d8892486de87", | ||
168 | "name": "Kampusareena", | 168 | "name": "Kampusareena", | ||
169 | "state": "active", | 169 | "state": "active", | ||
170 | "vocabulary_id": null | 170 | "vocabulary_id": null | ||
171 | }, | 171 | }, | ||
172 | { | 172 | { | ||
173 | "display_name": "electricity", | 173 | "display_name": "electricity", | ||
174 | "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", | 174 | "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", | ||
175 | "name": "electricity", | 175 | "name": "electricity", | ||
176 | "state": "active", | 176 | "state": "active", | ||
177 | "vocabulary_id": null | 177 | "vocabulary_id": null | ||
178 | }, | 178 | }, | ||
179 | { | 179 | { | ||
180 | "display_name": "solar power", | 180 | "display_name": "solar power", | ||
181 | "id": "20afb7a2-23ce-4ac4-9771-11daa2964f88", | 181 | "id": "20afb7a2-23ce-4ac4-9771-11daa2964f88", | ||
182 | "name": "solar power", | 182 | "name": "solar power", | ||
183 | "state": "active", | 183 | "state": "active", | ||
184 | "vocabulary_id": null | 184 | "vocabulary_id": null | ||
185 | } | 185 | } | ||
186 | ], | 186 | ], | ||
187 | "temporal_resolution": "1 second", | 187 | "temporal_resolution": "1 second", | ||
188 | "temporal_start": "2018-05-17", | 188 | "temporal_start": "2018-05-17", | ||
189 | "title": "Kampusareena solar power plant inverters", | 189 | "title": "Kampusareena solar power plant inverters", | ||
190 | "type": "dataset", | 190 | "type": "dataset", | ||
191 | "url": "", | 191 | "url": "", | ||
192 | "version": "" | 192 | "version": "" | ||
193 | } | 193 | } |