Changes
On January 12, 2025 at 9:37:42 AM +0200, Antti Hildén:
-
Changed title to Kampusareena tenants' electricity consumption and power quality (previously Kampusareena tenants' electricity power consumption and quality)
f | 1 | { | f | 1 | { |
2 | "author": "", | 2 | "author": "", | ||
3 | "author_email": "", | 3 | "author_email": "", | ||
4 | "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", | 4 | "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", | ||
5 | "data_owner": "University Properties of Finland", | 5 | "data_owner": "University Properties of Finland", | ||
6 | "groups": [ | 6 | "groups": [ | ||
7 | { | 7 | { | ||
n | 8 | "description": "This group collects together data sets related | n | 8 | "description": "This group collects together datasets related to |
9 | to the | 9 | the | ||
10 | ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) | 10 | ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) | ||
11 | building. Kampusareena is a modern office building that provides | 11 | building. Kampusareena is a modern office building that provides | ||
12 | spaces for the personnel of companies, university staff and students, | 12 | spaces for the personnel of companies, university staff and students, | ||
13 | and e.g, for the library of the whole campus. The building was | 13 | and e.g, for the library of the whole campus. The building was | ||
14 | completed in 2015 and is located on the Hervanta campus of Tampere | 14 | completed in 2015 and is located on the Hervanta campus of Tampere | ||
15 | University. Its total area is 16 000 square meters spread out over 8 | 15 | University. Its total area is 16 000 square meters spread out over 8 | ||
16 | floors.\r\n\r\nThe building uses district heating and is cooled with | 16 | floors.\r\n\r\nThe building uses district heating and is cooled with | ||
17 | two cooling machines with the electrical compressor powers of 170 kW | 17 | two cooling machines with the electrical compressor powers of 170 kW | ||
n | 18 | and 226 kW. Ventilation of the building consumes around 100 kW at | n | 18 | and 226 kW. Ventilation of the building consumes around 138 kW at |
19 | maximum. Other electrical loads of the building include two elevators | 19 | maximum. Other electrical loads of the building include two elevators | ||
n | 20 | (max. 7 kW each), eight electric car charging spots (max. 22 kW each) | n | 20 | (max. 7 kW each), eight electric vehicle charging spots (max. 22 kW |
21 | and appliances used by tenants (max. 350 kW). Additionally, the | 21 | each) and appliances used by tenants (approx. 350 kW at maximum). | ||
22 | building has 57 kW solar power plant. The building is connected to a | 22 | Additionally, the building has a 57 kW solar power plant. The building | ||
23 | medium voltage distribution network through 20/0.4 kV | 23 | is connected to a medium voltage distribution network through 20/0.4 | ||
24 | transformer.\r\nThe building automation system manages ventilation, | 24 | kV transformer.\r\nThe building automation system manages ventilation, | ||
25 | heating and cooling of the building. The system involves thousands of | 25 | heating and cooling of the building. The system involves thousands of | ||
26 | data points including indoor conditions of individual spaces, e.g. | 26 | data points including indoor conditions of individual spaces, e.g. | ||
27 | temperature and CO2 concentration, air \ufb02ows and set points for | 27 | temperature and CO2 concentration, air \ufb02ows and set points for | ||
28 | pumps. The electricity consumption of the tenants is measured with | 28 | pumps. The electricity consumption of the tenants is measured with | ||
29 | numerous simple power meters and a couple of more advanced power | 29 | numerous simple power meters and a couple of more advanced power | ||
n | 30 | meters are located at the main distribution boards. Additionally, nine | n | 30 | meters are located at the supply sides of two main distribution |
31 | power quality meters, called eQL Quality Meters, were installed at the | 31 | boards. Additionally, nine power quality meters, called eQL Quality | ||
32 | major loads of the building. These meters offer measured data of | 32 | Meters, were retrofitted at the major loads of the building. The | ||
33 | various electrical characteristics even with 100 millisecond time | 33 | electrical network and measurements are described in the master's | ||
34 | interval.\r\n\r\nMost of the data in this group is owned by University | 34 | thesis: https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nMost of the | ||
35 | Properties of Finlan (SYK). See the data owner of each dataset to | 35 | data in this group is owned by University Properties of Finland (SYK). | ||
36 | check if that particular data is owned by SYK. SYK has given | 36 | See the data owner of each dataset to check if that particular data is | ||
37 | permission to use the data for internal university research and | 37 | owned by SYK. Data owned by SYK is divided into two categories | ||
38 | education. So, for example, it cannot be shared with external parties | 38 | sensitive (unfiltered) and non sensitive (filtered). Sensitive data is | ||
39 | without a separate permission from SYK.", | 39 | related to the tenants of Kampusareena and is present in the [building | ||
40 | automation data | ||||
41 | /ckan.energydata.rd.tuni.fi/dataset/kampusareena-building-automation). | ||||
42 | In the available measurements list sensitive data is market as | ||||
43 | confidential. Different conditions apply with sensitive and | ||||
44 | non-sensitive data:\r\n\r\n- Non-sensitive data can be used freely in | ||||
45 | research and education use cases. Commercial usage has to be | ||||
46 | negotiated with University Properties of Finland.\r\n- Sensitive data | ||||
47 | can be used only by persons designated by the project leader. Data | ||||
48 | handling must be done in accordance with the information security | ||||
49 | policies of Tampere University.\r\n", | ||||
40 | "display_name": "Kampusareena", | 50 | "display_name": "Kampusareena", | ||
41 | "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", | 51 | "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", | ||
42 | "image_display_url": "", | 52 | "image_display_url": "", | ||
43 | "name": "kampusareena", | 53 | "name": "kampusareena", | ||
44 | "title": "Kampusareena" | 54 | "title": "Kampusareena" | ||
45 | }, | 55 | }, | ||
46 | { | 56 | { | ||
47 | "description": "This group collects together electrical | 57 | "description": "This group collects together electrical | ||
n | 48 | measurements collected with the commercial eQL Quality Meter. eQL is | n | 58 | measurements of the commercial eQL Quality Meter manufactured by |
49 | an advanced power quality meter. It collects basic electrical | 59 | Electrix. The meter comprises advanced power quality features in | ||
50 | measrurements such as power, current, voltage and cumulative energy, | 60 | addition to energy meter functionalities. The meter has been designed | ||
51 | but also advanced power quality measurements such as symmetrical | 61 | according to IEC 61000-4-30 Class S. The meter is able collect | ||
52 | components of voltage, and voltage and current harmonics up to 40th | 62 | continuous measurement quantities and event data (voltage dips and | ||
53 | order.\r\n\r\nHere is a list of some of the more commonly used | 63 | swells, rapid voltage changes, disturbance recordings and | ||
54 | measurements with their names and descriptions. These measurement | 64 | interruptions). A general list of continuous measurement quantities of | ||
55 | names can be found from the lists of available measurements for the | 65 | the meter is found below. Dataset specific measurement quantity lists | ||
56 | datasets in this group.\r\n\r\n- freq: frequency\r\n- P: active | 66 | may not include all of these measurement quantities.\r\n\r\n* | ||
57 | power\r\n- EP+: Total amount of energy produced or consumed since the | 67 | fundamental frequency\r\n* voltage\r\n* current\r\n* active power\r\n* | ||
58 | metering was started until the current measurement time.", | 68 | fundamental frequency reactive power\r\n* apparent power\r\n* Fryze's | ||
69 | reactive power (nonactive power)\r\n* energy\r\n* total distortion of | ||||
70 | voltage\r\n* total distortion of current\r\n* harmonic voltage | ||||
71 | (1st-40th order)\r\n* harmonic current (1st-40th order)\r\n* negative | ||||
72 | sequence component of voltage\r\n* zero sequence component of | ||||
73 | voltage\r\n* DC voltage\r\n* DC current\r\n* power factor\r\n* | ||||
74 | displacement power factor\r\n* flicker\r\n* under and over deviation | ||||
75 | of voltage\r\n* minimum and maximum of voltage\r\n* minimum and | ||||
76 | maximum of current", | ||||
59 | "display_name": "eQL quality meter", | 77 | "display_name": "eQL quality meter", | ||
60 | "id": "e5df8df3-49ae-46b5-8e0c-1fda29b64896", | 78 | "id": "e5df8df3-49ae-46b5-8e0c-1fda29b64896", | ||
61 | "image_display_url": "", | 79 | "image_display_url": "", | ||
62 | "name": "eql-quality-meter", | 80 | "name": "eql-quality-meter", | ||
63 | "title": "eQL quality meter" | 81 | "title": "eQL quality meter" | ||
64 | } | 82 | } | ||
65 | ], | 83 | ], | ||
66 | "id": "4dda6499-6c5f-4b0b-b205-b2e2392f1c40", | 84 | "id": "4dda6499-6c5f-4b0b-b205-b2e2392f1c40", | ||
67 | "isopen": false, | 85 | "isopen": false, | ||
68 | "license_id": "internal", | 86 | "license_id": "internal", | ||
69 | "license_title": "For internal research and education use", | 87 | "license_title": "For internal research and education use", | ||
70 | "maintainer": "Antti Hilden", | 88 | "maintainer": "Antti Hilden", | ||
71 | "maintainer_email": "antti.t.hilden@tuni.fi", | 89 | "maintainer_email": "antti.t.hilden@tuni.fi", | ||
72 | "metadata_created": "2022-12-15T14:02:28.427082", | 90 | "metadata_created": "2022-12-15T14:02:28.427082", | ||
n | 73 | "metadata_modified": "2023-02-01T08:38:10.264952", | n | 91 | "metadata_modified": "2025-01-12T07:37:42.064899", |
74 | "name": | 92 | "name": | ||
75 | usareena-mains-of-tenant-s-electricity-power-consumption-and-quality", | 93 | usareena-mains-of-tenant-s-electricity-power-consumption-and-quality", | ||
76 | "notes": "Various electrical measurements related to the total power | 94 | "notes": "Various electrical measurements related to the total power | ||
77 | consumption of the tenants of Kampusareena. Covers for example power | 95 | consumption of the tenants of Kampusareena. Covers for example power | ||
78 | used for lighting and power sockets. Includes basic electrical | 96 | used for lighting and power sockets. Includes basic electrical | ||
79 | measrurements such as power, current, voltage and cumulative energy, | 97 | measrurements such as power, current, voltage and cumulative energy, | ||
80 | but also advanced power quality measurements such as symmetrical | 98 | but also advanced power quality measurements such as symmetrical | ||
81 | components of voltage, and voltage and current harmonics.\r\n\r\nSee | 99 | components of voltage, and voltage and current harmonics.\r\n\r\nSee | ||
82 | the | 100 | the | ||
83 | [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) | 101 | [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) | ||
84 | project for general information about how the measurements are stored | 102 | project for general information about how the measurements are stored | ||
85 | and can be used. See the [eQL quality | 103 | and can be used. See the [eQL quality | ||
86 | ter](https://ckan.energydata.rd.tuni.fi/group/about/eql-quality-meter) | 104 | ter](https://ckan.energydata.rd.tuni.fi/group/about/eql-quality-meter) | ||
87 | group for general information about the used measurement device. See | 105 | group for general information about the used measurement device. See | ||
88 | the | 106 | the | ||
89 | usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) | 107 | usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) | ||
90 | group for general information about the building.", | 108 | group for general information about the building.", | ||
91 | "num_resources": 1, | 109 | "num_resources": 1, | ||
92 | "num_tags": 3, | 110 | "num_tags": 3, | ||
93 | "organization": { | 111 | "organization": { | ||
94 | "approval_status": "approved", | 112 | "approval_status": "approved", | ||
95 | "created": "2022-10-14T17:57:03.019118", | 113 | "created": "2022-10-14T17:57:03.019118", | ||
96 | "description": "The ProCem ([Social Energy - Prosumer Centric | 114 | "description": "The ProCem ([Social Energy - Prosumer Centric | ||
97 | Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and | 115 | Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and | ||
98 | ProCemPlus ([Prosumer Centric Energy Communities - towards Energy | 116 | ProCemPlus ([Prosumer Centric Energy Communities - towards Energy | ||
99 | Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have | 117 | Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have | ||
100 | collected energy and energy community related data from the | 118 | collected energy and energy community related data from the | ||
101 | [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) | 119 | [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) | ||
102 | building in the Hervanta campus, the | 120 | building in the Hervanta campus, the | ||
103 | [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) | 121 | [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) | ||
104 | micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data | 122 | micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data | ||
105 | sources.\r\n\r\nThe data for all of the datasets provided by ProCem | 123 | sources.\r\n\r\nThe data for all of the datasets provided by ProCem | ||
106 | have been collected using a custom data collection platform developed | 124 | have been collected using a custom data collection platform developed | ||
107 | as part of the projects. Thus all the data is stored in the same way | 125 | as part of the projects. Thus all the data is stored in the same way | ||
108 | and in the same format and accessing all the data happens in the same | 126 | and in the same format and accessing all the data happens in the same | ||
109 | way. If you are interested in learning more about the data collection | 127 | way. If you are interested in learning more about the data collection | ||
110 | platform, it has been described in a scientific article titled \"[A | 128 | platform, it has been described in a scientific article titled \"[A | ||
111 | Data Collection and Supplementary Control Platform of a Modern | 129 | Data Collection and Supplementary Control Platform of a Modern | ||
112 | Building for Smart Energy | 130 | Building for Smart Energy | ||
113 | ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe | 131 | ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe | ||
n | 114 | data is stored in simple CSV files on a network drive where select | n | 132 | data is stored in simple CSV files on a network drive to which select |
115 | project researchers have access to. All data from a measurement target | 133 | project researchers have access to. All data from a measurement target | ||
n | 116 | (Kampusarreenao or Marjam\u00e4ki) for a day are stored in one file. | n | 134 | (Kampusareena or Marjam\u00e4ki) for a day are stored in one file. One |
117 | One line of this CSV file contains these 3 items separated by a | 135 | line of this CSV file contains these 3 items separated by a tab | ||
118 | tab:\r\n\r\n- id: Each measurement point has a unique id number. These | 136 | character:\r\n\r\n- **id**: Each measurement point has a unique id | ||
119 | are documented in the list of available measurements for each | 137 | number. These are documented in the lists of the available | ||
120 | dataset.\r\n- value: The actual measurment value.\r\n- timestamp: Unix | 138 | measurements for each dataset.\r\n- **value**: The actual measurement | ||
121 | time in milliseconds i.e. milliseconds since 1970-01-01 00:00 UTC | 139 | value.\r\n- **timestamp**: Unix time in milliseconds i.e. milliseconds | ||
122 | time.\r\n\r\nIf you want to see a small example of how these files | 140 | since 1970-01-01 00:00 UTC time.\r\n\r\nIf you want to see a small | ||
123 | look like, you can check [this sample data dataset | 141 | example of how these files look like, you can check [this sample | ||
124 | ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf | 142 | ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf | ||
125 | you are interested in getting some data from the ProCem datasets, you | 143 | you are interested in getting some data from the ProCem datasets, you | ||
126 | can contact the person marked as the dataset maintainer. Since the raw | 144 | can contact the person marked as the dataset maintainer. Since the raw | ||
127 | data files are very large and contain data sensitive to the data | 145 | data files are very large and contain data sensitive to the data | ||
n | 128 | owner, you will be provided filtered versions of the data files | n | 146 | owner, you will be provided with filtered versions of the data files |
129 | containing only the data you require from the time period you want. So | 147 | containing only the data you require from the time period you want. | ||
130 | if you already know precisely what data you want and from what time | 148 | So, if you already know precisely what data you want and from what | ||
131 | period, you can provide the measurement ids of the measurements you | 149 | time period, you can provide the measurement ids of the measurements | ||
132 | want and a range of dates.\r\n\r\nNote: Though generally the data | 150 | you want with the range of dates.\r\n\r\nNote, though generally the | ||
133 | collection has been continuous since the date marked as measurement | 151 | data collection has been continuous since the date marked as the | ||
134 | start date, various issues with measurement devices, networking or the | 152 | measurement start date, various issues with measurement devices, | ||
135 | collection system have caused breaks in data collection varying from | 153 | networking or the collection system have caused breaks in data | ||
136 | minutes to days. So please take this into account when processing your | 154 | collection varying from minutes to days. So please take this into | ||
137 | data.", | 155 | account when processing your data.", | ||
138 | "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | 156 | "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | ||
139 | "image_url": "", | 157 | "image_url": "", | ||
140 | "is_organization": true, | 158 | "is_organization": true, | ||
141 | "name": "procem", | 159 | "name": "procem", | ||
142 | "state": "active", | 160 | "state": "active", | ||
143 | "title": "ProCem", | 161 | "title": "ProCem", | ||
144 | "type": "organization" | 162 | "type": "organization" | ||
145 | }, | 163 | }, | ||
146 | "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | 164 | "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | ||
147 | "private": false, | 165 | "private": false, | ||
148 | "relationships_as_object": [], | 166 | "relationships_as_object": [], | ||
149 | "relationships_as_subject": [], | 167 | "relationships_as_subject": [], | ||
150 | "resources": [ | 168 | "resources": [ | ||
151 | { | 169 | { | ||
152 | "cache_last_updated": null, | 170 | "cache_last_updated": null, | ||
153 | "cache_url": null, | 171 | "cache_url": null, | ||
154 | "created": "2023-02-01T08:27:56.244584", | 172 | "created": "2023-02-01T08:27:56.244584", | ||
155 | "datastore_active": true, | 173 | "datastore_active": true, | ||
156 | "description": "List of available measurements.", | 174 | "description": "List of available measurements.", | ||
157 | "format": "XLSX", | 175 | "format": "XLSX", | ||
158 | "hash": "", | 176 | "hash": "", | ||
159 | "id": "1556a1c9-fba3-4674-a629-ae7c30400737", | 177 | "id": "1556a1c9-fba3-4674-a629-ae7c30400737", | ||
160 | "last_modified": "2023-02-01T08:27:56.220957", | 178 | "last_modified": "2023-02-01T08:27:56.220957", | ||
161 | "metadata_modified": "2023-02-01T08:27:56.231019", | 179 | "metadata_modified": "2023-02-01T08:27:56.231019", | ||
162 | "mimetype": | 180 | "mimetype": | ||
163 | "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", | 181 | "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", | ||
164 | "mimetype_inner": null, | 182 | "mimetype_inner": null, | ||
165 | "name": | 183 | "name": | ||
166 | "tenants_electricity_power_quality_available_measurements.xlsx", | 184 | "tenants_electricity_power_quality_available_measurements.xlsx", | ||
167 | "package_id": "4dda6499-6c5f-4b0b-b205-b2e2392f1c40", | 185 | "package_id": "4dda6499-6c5f-4b0b-b205-b2e2392f1c40", | ||
168 | "position": 0, | 186 | "position": 0, | ||
169 | "resource_type": null, | 187 | "resource_type": null, | ||
170 | "size": 15128, | 188 | "size": 15128, | ||
171 | "state": "active", | 189 | "state": "active", | ||
172 | "url": | 190 | "url": | ||
173 | e7c30400737/download/tenants_electricity_available_measurements.xlsx", | 191 | e7c30400737/download/tenants_electricity_available_measurements.xlsx", | ||
174 | "url_type": "upload" | 192 | "url_type": "upload" | ||
175 | } | 193 | } | ||
176 | ], | 194 | ], | ||
177 | "state": "active", | 195 | "state": "active", | ||
178 | "tags": [ | 196 | "tags": [ | ||
179 | { | 197 | { | ||
180 | "display_name": "Kampusareena", | 198 | "display_name": "Kampusareena", | ||
181 | "id": "509dbd7e-76cf-40b1-801b-d8892486de87", | 199 | "id": "509dbd7e-76cf-40b1-801b-d8892486de87", | ||
182 | "name": "Kampusareena", | 200 | "name": "Kampusareena", | ||
183 | "state": "active", | 201 | "state": "active", | ||
184 | "vocabulary_id": null | 202 | "vocabulary_id": null | ||
185 | }, | 203 | }, | ||
186 | { | 204 | { | ||
187 | "display_name": "electricity", | 205 | "display_name": "electricity", | ||
188 | "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", | 206 | "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", | ||
189 | "name": "electricity", | 207 | "name": "electricity", | ||
190 | "state": "active", | 208 | "state": "active", | ||
191 | "vocabulary_id": null | 209 | "vocabulary_id": null | ||
192 | }, | 210 | }, | ||
193 | { | 211 | { | ||
194 | "display_name": "power quality", | 212 | "display_name": "power quality", | ||
195 | "id": "f75b4ff7-2ba6-44ba-8468-c1e9c3ba08e4", | 213 | "id": "f75b4ff7-2ba6-44ba-8468-c1e9c3ba08e4", | ||
196 | "name": "power quality", | 214 | "name": "power quality", | ||
197 | "state": "active", | 215 | "state": "active", | ||
198 | "vocabulary_id": null | 216 | "vocabulary_id": null | ||
199 | } | 217 | } | ||
200 | ], | 218 | ], | ||
201 | "temporal_resolution": "1 second", | 219 | "temporal_resolution": "1 second", | ||
202 | "temporal_start": "2018-05-17", | 220 | "temporal_start": "2018-05-17", | ||
t | 203 | "title": "Kampusareena tenants' electricity power consumption and | t | 221 | "title": "Kampusareena tenants' electricity consumption and power |
204 | quality", | 222 | quality", | ||
205 | "type": "dataset", | 223 | "type": "dataset", | ||
206 | "url": "", | 224 | "url": "", | ||
207 | "version": "" | 225 | "version": "" | ||
208 | } | 226 | } |