Changes
On January 14, 2025 at 12:10:33 PM +0200, hylli:
-
Changed title to Kampusareena cooling machines ëlectricity consumption and power quality (previously Kampusareena cooling machines consumption and power quality)
f | 1 | { | f | 1 | { |
2 | "author": "", | 2 | "author": "", | ||
3 | "author_email": "", | 3 | "author_email": "", | ||
4 | "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", | 4 | "creator_user_id": "c028eea2-1878-47b8-843b-aa298066c249", | ||
5 | "data_owner": "University Properties of Finland", | 5 | "data_owner": "University Properties of Finland", | ||
6 | "groups": [ | 6 | "groups": [ | ||
7 | { | 7 | { | ||
8 | "description": "This group collects together datasets related to | 8 | "description": "This group collects together datasets related to | ||
9 | the | 9 | the | ||
10 | ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) | 10 | ving-collaboration-platform-hervanta-campus#switcher-trigger-overview) | ||
11 | building. Kampusareena is a modern office building that provides | 11 | building. Kampusareena is a modern office building that provides | ||
12 | spaces for the personnel of companies, university staff and students, | 12 | spaces for the personnel of companies, university staff and students, | ||
13 | and e.g, for the library of the whole campus. The building was | 13 | and e.g, for the library of the whole campus. The building was | ||
14 | completed in 2015 and is located on the Hervanta campus of Tampere | 14 | completed in 2015 and is located on the Hervanta campus of Tampere | ||
15 | University. Its total area is 16 000 square meters spread out over 8 | 15 | University. Its total area is 16 000 square meters spread out over 8 | ||
16 | floors.\r\n\r\nThe building uses district heating and is cooled with | 16 | floors.\r\n\r\nThe building uses district heating and is cooled with | ||
17 | two cooling machines with the electrical compressor powers of 170 kW | 17 | two cooling machines with the electrical compressor powers of 170 kW | ||
18 | and 226 kW. Ventilation of the building consumes around 138 kW at | 18 | and 226 kW. Ventilation of the building consumes around 138 kW at | ||
19 | maximum. Other electrical loads of the building include two elevators | 19 | maximum. Other electrical loads of the building include two elevators | ||
20 | (max. 7 kW each), eight electric vehicle charging spots (max. 22 kW | 20 | (max. 7 kW each), eight electric vehicle charging spots (max. 22 kW | ||
21 | each) and appliances used by tenants (approx. 350 kW at maximum). | 21 | each) and appliances used by tenants (approx. 350 kW at maximum). | ||
22 | Additionally, the building has a 57 kW solar power plant. The building | 22 | Additionally, the building has a 57 kW solar power plant. The building | ||
23 | is connected to a medium voltage distribution network through 20/0.4 | 23 | is connected to a medium voltage distribution network through 20/0.4 | ||
24 | kV transformer.\r\nThe building automation system manages ventilation, | 24 | kV transformer.\r\nThe building automation system manages ventilation, | ||
25 | heating and cooling of the building. The system involves thousands of | 25 | heating and cooling of the building. The system involves thousands of | ||
26 | data points including indoor conditions of individual spaces, e.g. | 26 | data points including indoor conditions of individual spaces, e.g. | ||
27 | temperature and CO2 concentration, air \ufb02ows and set points for | 27 | temperature and CO2 concentration, air \ufb02ows and set points for | ||
28 | pumps. The electricity consumption of the tenants is measured with | 28 | pumps. The electricity consumption of the tenants is measured with | ||
29 | numerous simple power meters and a couple of more advanced power | 29 | numerous simple power meters and a couple of more advanced power | ||
30 | meters are located at the supply sides of two main distribution | 30 | meters are located at the supply sides of two main distribution | ||
31 | boards. Additionally, nine power quality meters, called eQL Quality | 31 | boards. Additionally, nine power quality meters, called eQL Quality | ||
32 | Meters, were retrofitted at the major loads of the building. The | 32 | Meters, were retrofitted at the major loads of the building. The | ||
33 | electrical network and measurements are described in the master's | 33 | electrical network and measurements are described in the master's | ||
34 | thesis: https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nMost of the | 34 | thesis: https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nMost of the | ||
35 | data in this group is owned by University Properties of Finland (SYK). | 35 | data in this group is owned by University Properties of Finland (SYK). | ||
36 | See the data owner of each dataset to check if that particular data is | 36 | See the data owner of each dataset to check if that particular data is | ||
37 | owned by SYK. Data owned by SYK is divided into two categories | 37 | owned by SYK. Data owned by SYK is divided into two categories | ||
38 | sensitive (unfiltered) and non sensitive (filtered). Sensitive data is | 38 | sensitive (unfiltered) and non sensitive (filtered). Sensitive data is | ||
39 | related to the tenants of Kampusareena and is present in the [building | 39 | related to the tenants of Kampusareena and is present in the [building | ||
40 | automation data | 40 | automation data | ||
41 | /ckan.energydata.rd.tuni.fi/dataset/kampusareena-building-automation). | 41 | /ckan.energydata.rd.tuni.fi/dataset/kampusareena-building-automation). | ||
42 | In the available measurements list sensitive data is market as | 42 | In the available measurements list sensitive data is market as | ||
43 | confidential. Different conditions apply with sensitive and | 43 | confidential. Different conditions apply with sensitive and | ||
44 | non-sensitive data:\r\n\r\n- Non-sensitive data can be used freely in | 44 | non-sensitive data:\r\n\r\n- Non-sensitive data can be used freely in | ||
45 | research and education use cases. Commercial usage has to be | 45 | research and education use cases. Commercial usage has to be | ||
46 | negotiated with University Properties of Finland.\r\n- Sensitive data | 46 | negotiated with University Properties of Finland.\r\n- Sensitive data | ||
47 | can be used only by persons designated by the project leader. Data | 47 | can be used only by persons designated by the project leader. Data | ||
48 | handling must be done in accordance with the information security | 48 | handling must be done in accordance with the information security | ||
49 | policies of Tampere University.\r\n", | 49 | policies of Tampere University.\r\n", | ||
50 | "display_name": "Kampusareena", | 50 | "display_name": "Kampusareena", | ||
51 | "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", | 51 | "id": "0b59cd26-0db5-44b4-9e51-8bb07cfeb0f3", | ||
52 | "image_display_url": "", | 52 | "image_display_url": "", | ||
53 | "name": "kampusareena", | 53 | "name": "kampusareena", | ||
54 | "title": "Kampusareena" | 54 | "title": "Kampusareena" | ||
55 | }, | 55 | }, | ||
56 | { | 56 | { | ||
57 | "description": "This group collects together electrical | 57 | "description": "This group collects together electrical | ||
58 | measurements of the commercial eQL Quality Meter manufactured by | 58 | measurements of the commercial eQL Quality Meter manufactured by | ||
59 | Electrix. The meter comprises advanced power quality features in | 59 | Electrix. The meter comprises advanced power quality features in | ||
60 | addition to energy meter functionalities. The meter has been designed | 60 | addition to energy meter functionalities. The meter has been designed | ||
61 | according to IEC 61000-4-30 Class S. The meter is able collect | 61 | according to IEC 61000-4-30 Class S. The meter is able collect | ||
62 | continuous measurement quantities and event data (voltage dips and | 62 | continuous measurement quantities and event data (voltage dips and | ||
63 | swells, rapid voltage changes, disturbance recordings and | 63 | swells, rapid voltage changes, disturbance recordings and | ||
64 | interruptions). A general list of continuous measurement quantities of | 64 | interruptions). A general list of continuous measurement quantities of | ||
65 | the meter is found below. Dataset specific measurement quantity lists | 65 | the meter is found below. Dataset specific measurement quantity lists | ||
66 | may not include all of these measurement quantities.\r\n\r\n* | 66 | may not include all of these measurement quantities.\r\n\r\n* | ||
67 | fundamental frequency\r\n* voltage\r\n* current\r\n* active power\r\n* | 67 | fundamental frequency\r\n* voltage\r\n* current\r\n* active power\r\n* | ||
68 | fundamental frequency reactive power\r\n* apparent power\r\n* Fryze's | 68 | fundamental frequency reactive power\r\n* apparent power\r\n* Fryze's | ||
69 | reactive power (nonactive power)\r\n* energy\r\n* total distortion of | 69 | reactive power (nonactive power)\r\n* energy\r\n* total distortion of | ||
70 | voltage\r\n* total distortion of current\r\n* harmonic voltage | 70 | voltage\r\n* total distortion of current\r\n* harmonic voltage | ||
71 | (1st-40th order)\r\n* harmonic current (1st-40th order)\r\n* negative | 71 | (1st-40th order)\r\n* harmonic current (1st-40th order)\r\n* negative | ||
72 | sequence component of voltage\r\n* zero sequence component of | 72 | sequence component of voltage\r\n* zero sequence component of | ||
73 | voltage\r\n* DC voltage\r\n* DC current\r\n* power factor\r\n* | 73 | voltage\r\n* DC voltage\r\n* DC current\r\n* power factor\r\n* | ||
74 | displacement power factor\r\n* flicker\r\n* under and over deviation | 74 | displacement power factor\r\n* flicker\r\n* under and over deviation | ||
75 | of voltage\r\n* minimum and maximum of voltage\r\n* minimum and | 75 | of voltage\r\n* minimum and maximum of voltage\r\n* minimum and | ||
76 | maximum of current", | 76 | maximum of current", | ||
77 | "display_name": "eQL quality meter", | 77 | "display_name": "eQL quality meter", | ||
78 | "id": "e5df8df3-49ae-46b5-8e0c-1fda29b64896", | 78 | "id": "e5df8df3-49ae-46b5-8e0c-1fda29b64896", | ||
79 | "image_display_url": "", | 79 | "image_display_url": "", | ||
80 | "name": "eql-quality-meter", | 80 | "name": "eql-quality-meter", | ||
81 | "title": "eQL quality meter" | 81 | "title": "eQL quality meter" | ||
82 | } | 82 | } | ||
83 | ], | 83 | ], | ||
84 | "id": "072210a3-7ab5-4413-9461-935164c376fb", | 84 | "id": "072210a3-7ab5-4413-9461-935164c376fb", | ||
85 | "isopen": false, | 85 | "isopen": false, | ||
86 | "license_id": "internal", | 86 | "license_id": "internal", | ||
87 | "license_title": "For internal research and education use", | 87 | "license_title": "For internal research and education use", | ||
88 | "maintainer": "Antti Hilden", | 88 | "maintainer": "Antti Hilden", | ||
89 | "maintainer_email": "antti.t.hilden@tuni.fi", | 89 | "maintainer_email": "antti.t.hilden@tuni.fi", | ||
90 | "metadata_created": "2022-12-16T08:13:42.663062", | 90 | "metadata_created": "2022-12-16T08:13:42.663062", | ||
n | 91 | "metadata_modified": "2025-01-12T13:05:23.851540", | n | 91 | "metadata_modified": "2025-01-14T10:10:33.253284", |
92 | "name": | 92 | "name": | ||
93 | "kampusareena-cooling-machines-power-consumption-and-quality", | 93 | "kampusareena-cooling-machines-power-consumption-and-quality", | ||
94 | "notes": "Electrical measurement data of two cooling machines in | 94 | "notes": "Electrical measurement data of two cooling machines in | ||
95 | Kampusareena in Tampere. The cooling machines are used to cool the | 95 | Kampusareena in Tampere. The cooling machines are used to cool the | ||
96 | indoor air of the building. The electrical maximum powers of the | 96 | indoor air of the building. The electrical maximum powers of the | ||
97 | cooling machines 1 and 2 are 226 kW and 170 kW, respectively. The | 97 | cooling machines 1 and 2 are 226 kW and 170 kW, respectively. The | ||
98 | cooling machines have been a part of a FCR-N reserve unit pool since | 98 | cooling machines have been a part of a FCR-N reserve unit pool since | ||
99 | September 2020. The cooling machines are manufactured by Chiller and | 99 | September 2020. The cooling machines are manufactured by Chiller and | ||
100 | their models are:\r\n\r\n* Cooling machine 1: | 100 | their models are:\r\n\r\n* Cooling machine 1: | ||
101 | 110-4D-X-P1-W2-F3-WC-ECO-WO-R410A-DR-CR-VN-CE3-B-SN-PH-PL-EQN\r\n\r\n* | 101 | 110-4D-X-P1-W2-F3-WC-ECO-WO-R410A-DR-CR-VN-CE3-B-SN-PH-PL-EQN\r\n\r\n* | ||
102 | Cooling machine 2: | 102 | Cooling machine 2: | ||
103 | GIW-150-6D-X-P1-F3-TCV-WO-R410A-DR-CR-VN-CE3-B-SN-PH-PL-EQN\r\n\r\nThe | 103 | GIW-150-6D-X-P1-F3-TCV-WO-R410A-DR-CR-VN-CE3-B-SN-PH-PL-EQN\r\n\r\nThe | ||
104 | data includes 179 continuous timeseries measurement quantities | 104 | data includes 179 continuous timeseries measurement quantities | ||
105 | aggregated at 1-second interval. The measurement quantities consist of | 105 | aggregated at 1-second interval. The measurement quantities consist of | ||
106 | voltage, current, power and energy, and power quality quantities such | 106 | voltage, current, power and energy, and power quality quantities such | ||
107 | as symmetrical components of voltage, and harmonic voltages and | 107 | as symmetrical components of voltage, and harmonic voltages and | ||
108 | currents. The measurement points are at the feeders of the cooling | 108 | currents. The measurement points are at the feeders of the cooling | ||
109 | machines at the main distribution board. For details about the | 109 | machines at the main distribution board. For details about the | ||
110 | measurements see the master's thesis: | 110 | measurements see the master's thesis: | ||
111 | https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nNOTE: EP+ | 111 | https://urn.fi/URN:NBN:fi:tty-201811222711\r\n\r\nNOTE: EP+ | ||
112 | (cumulative energy import) is half of the actual value due to a bug in | 112 | (cumulative energy import) is half of the actual value due to a bug in | ||
113 | the measurement.\r\n\r\nSee the | 113 | the measurement.\r\n\r\nSee the | ||
114 | [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) | 114 | [ProCem](https://ckan.energydata.rd.tuni.fi/organization/about/procem) | ||
115 | project for general information about how the measurements are stored | 115 | project for general information about how the measurements are stored | ||
116 | and can be used. See the [eQL quality | 116 | and can be used. See the [eQL quality | ||
117 | ter](https://ckan.energydata.rd.tuni.fi/group/about/eql-quality-meter) | 117 | ter](https://ckan.energydata.rd.tuni.fi/group/about/eql-quality-meter) | ||
118 | group for general information about the used measurement device. See | 118 | group for general information about the used measurement device. See | ||
119 | the | 119 | the | ||
120 | usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) | 120 | usareena](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena) | ||
121 | group for general information about the building.", | 121 | group for general information about the building.", | ||
122 | "num_resources": 1, | 122 | "num_resources": 1, | ||
123 | "num_tags": 4, | 123 | "num_tags": 4, | ||
124 | "organization": { | 124 | "organization": { | ||
125 | "approval_status": "approved", | 125 | "approval_status": "approved", | ||
126 | "created": "2022-10-14T17:57:03.019118", | 126 | "created": "2022-10-14T17:57:03.019118", | ||
127 | "description": "The ProCem ([Social Energy - Prosumer Centric | 127 | "description": "The ProCem ([Social Energy - Prosumer Centric | ||
128 | Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and | 128 | Energy Ecosystem](http://www.senecc.fi/projects/procem-2)) and | ||
129 | ProCemPlus ([Prosumer Centric Energy Communities - towards Energy | 129 | ProCemPlus ([Prosumer Centric Energy Communities - towards Energy | ||
130 | Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have | 130 | Ecosystem](https://www.senecc.fi/projects/procemplus)) projects have | ||
131 | collected energy and energy community related data from the | 131 | collected energy and energy community related data from the | ||
132 | [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) | 132 | [Kampusareena](https://ckan.energydata.rd.tuni.fi/group/kampusareena) | ||
133 | building in the Hervanta campus, the | 133 | building in the Hervanta campus, the | ||
134 | [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) | 134 | [Marjam\u00e4ki](https://ckan.energydata.rd.tuni.fi/group/marjamaki) | ||
135 | micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data | 135 | micro-grid area in Lemp\u00e4\u00e4l\u00e4 and open data | ||
136 | sources.\r\n\r\nThe data for all of the datasets provided by ProCem | 136 | sources.\r\n\r\nThe data for all of the datasets provided by ProCem | ||
137 | have been collected using a custom data collection platform developed | 137 | have been collected using a custom data collection platform developed | ||
138 | as part of the projects. Thus all the data is stored in the same way | 138 | as part of the projects. Thus all the data is stored in the same way | ||
139 | and in the same format and accessing all the data happens in the same | 139 | and in the same format and accessing all the data happens in the same | ||
140 | way. If you are interested in learning more about the data collection | 140 | way. If you are interested in learning more about the data collection | ||
141 | platform, it has been described in a scientific article titled \"[A | 141 | platform, it has been described in a scientific article titled \"[A | ||
142 | Data Collection and Supplementary Control Platform of a Modern | 142 | Data Collection and Supplementary Control Platform of a Modern | ||
143 | Building for Smart Energy | 143 | Building for Smart Energy | ||
144 | ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe | 144 | ct.com/science/article/pii/S2352467722001734?via%3Dihub)\".\r\n\r\nThe | ||
145 | data is stored in simple CSV files on a network drive to which select | 145 | data is stored in simple CSV files on a network drive to which select | ||
146 | project researchers have access to. All data from a measurement target | 146 | project researchers have access to. All data from a measurement target | ||
147 | (Kampusareena or Marjam\u00e4ki) for a day are stored in one file. One | 147 | (Kampusareena or Marjam\u00e4ki) for a day are stored in one file. One | ||
148 | line of this CSV file contains these 3 items separated by a tab | 148 | line of this CSV file contains these 3 items separated by a tab | ||
149 | character:\r\n\r\n- **id**: Each measurement point has a unique id | 149 | character:\r\n\r\n- **id**: Each measurement point has a unique id | ||
150 | number. These are documented in the lists of the available | 150 | number. These are documented in the lists of the available | ||
151 | measurements for each dataset.\r\n- **value**: The actual measurement | 151 | measurements for each dataset.\r\n- **value**: The actual measurement | ||
152 | value.\r\n- **timestamp**: Unix time in milliseconds i.e. milliseconds | 152 | value.\r\n- **timestamp**: Unix time in milliseconds i.e. milliseconds | ||
153 | since 1970-01-01 00:00 UTC time.\r\n\r\nIf you want to see a small | 153 | since 1970-01-01 00:00 UTC time.\r\n\r\nIf you want to see a small | ||
154 | example of how these files look like, you can check [this sample | 154 | example of how these files look like, you can check [this sample | ||
155 | ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf | 155 | ower-quality/resource/0abf89c6-bba6-4d5a-b45f-1f40fd9c5129).\r\n\r\nIf | ||
156 | you are interested in getting some data from the ProCem datasets, you | 156 | you are interested in getting some data from the ProCem datasets, you | ||
157 | can contact the person marked as the dataset maintainer. Since the raw | 157 | can contact the person marked as the dataset maintainer. Since the raw | ||
158 | data files are very large and contain data sensitive to the data | 158 | data files are very large and contain data sensitive to the data | ||
159 | owner, you will be provided with filtered versions of the data files | 159 | owner, you will be provided with filtered versions of the data files | ||
160 | containing only the data you require from the time period you want. | 160 | containing only the data you require from the time period you want. | ||
161 | So, if you already know precisely what data you want and from what | 161 | So, if you already know precisely what data you want and from what | ||
162 | time period, you can provide the measurement ids of the measurements | 162 | time period, you can provide the measurement ids of the measurements | ||
163 | you want with the range of dates.\r\n\r\nNote, though generally the | 163 | you want with the range of dates.\r\n\r\nNote, though generally the | ||
164 | data collection has been continuous since the date marked as the | 164 | data collection has been continuous since the date marked as the | ||
165 | measurement start date, various issues with measurement devices, | 165 | measurement start date, various issues with measurement devices, | ||
166 | networking or the collection system have caused breaks in data | 166 | networking or the collection system have caused breaks in data | ||
167 | collection varying from minutes to days. So please take this into | 167 | collection varying from minutes to days. So please take this into | ||
168 | account when processing your data.", | 168 | account when processing your data.", | ||
169 | "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | 169 | "id": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | ||
170 | "image_url": "", | 170 | "image_url": "", | ||
171 | "is_organization": true, | 171 | "is_organization": true, | ||
172 | "name": "procem", | 172 | "name": "procem", | ||
173 | "state": "active", | 173 | "state": "active", | ||
174 | "title": "ProCem", | 174 | "title": "ProCem", | ||
175 | "type": "organization" | 175 | "type": "organization" | ||
176 | }, | 176 | }, | ||
177 | "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | 177 | "owner_org": "ec67e141-aa5e-46f7-b3ab-5a10c172e8e7", | ||
178 | "private": false, | 178 | "private": false, | ||
179 | "relationships_as_object": [], | 179 | "relationships_as_object": [], | ||
180 | "relationships_as_subject": [], | 180 | "relationships_as_subject": [], | ||
181 | "resources": [ | 181 | "resources": [ | ||
182 | { | 182 | { | ||
183 | "cache_last_updated": null, | 183 | "cache_last_updated": null, | ||
184 | "cache_url": null, | 184 | "cache_url": null, | ||
185 | "created": "2023-02-01T13:37:09.153064", | 185 | "created": "2023-02-01T13:37:09.153064", | ||
186 | "datastore_active": true, | 186 | "datastore_active": true, | ||
187 | "description": "List of available measurements.", | 187 | "description": "List of available measurements.", | ||
188 | "format": "XLSX", | 188 | "format": "XLSX", | ||
189 | "hash": "", | 189 | "hash": "", | ||
190 | "id": "7e5dbc9c-de6b-4716-b985-61a1f0b985b0", | 190 | "id": "7e5dbc9c-de6b-4716-b985-61a1f0b985b0", | ||
191 | "last_modified": "2023-02-01T13:37:09.122218", | 191 | "last_modified": "2023-02-01T13:37:09.122218", | ||
192 | "metadata_modified": "2023-02-01T13:37:09.136973", | 192 | "metadata_modified": "2023-02-01T13:37:09.136973", | ||
193 | "mimetype": | 193 | "mimetype": | ||
194 | "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", | 194 | "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet", | ||
195 | "mimetype_inner": null, | 195 | "mimetype_inner": null, | ||
196 | "name": | 196 | "name": | ||
197 | "water_cooling_machines_power_quality_available_measurements.xlsx", | 197 | "water_cooling_machines_power_quality_available_measurements.xlsx", | ||
198 | "package_id": "072210a3-7ab5-4413-9461-935164c376fb", | 198 | "package_id": "072210a3-7ab5-4413-9461-935164c376fb", | ||
199 | "position": 0, | 199 | "position": 0, | ||
200 | "resource_type": null, | 200 | "resource_type": null, | ||
201 | "size": 20824, | 201 | "size": 20824, | ||
202 | "state": "active", | 202 | "state": "active", | ||
203 | "url": | 203 | "url": | ||
204 | oad/water_cooling_machines_power_quality_available_measurements.xlsx", | 204 | oad/water_cooling_machines_power_quality_available_measurements.xlsx", | ||
205 | "url_type": "upload" | 205 | "url_type": "upload" | ||
206 | } | 206 | } | ||
207 | ], | 207 | ], | ||
208 | "state": "active", | 208 | "state": "active", | ||
209 | "tags": [ | 209 | "tags": [ | ||
210 | { | 210 | { | ||
211 | "display_name": "Kampusareena", | 211 | "display_name": "Kampusareena", | ||
212 | "id": "509dbd7e-76cf-40b1-801b-d8892486de87", | 212 | "id": "509dbd7e-76cf-40b1-801b-d8892486de87", | ||
213 | "name": "Kampusareena", | 213 | "name": "Kampusareena", | ||
214 | "state": "active", | 214 | "state": "active", | ||
215 | "vocabulary_id": null | 215 | "vocabulary_id": null | ||
216 | }, | 216 | }, | ||
217 | { | 217 | { | ||
218 | "display_name": "cooling", | 218 | "display_name": "cooling", | ||
219 | "id": "10512cf4-add6-455f-bd19-3fc354c5ea9a", | 219 | "id": "10512cf4-add6-455f-bd19-3fc354c5ea9a", | ||
220 | "name": "cooling", | 220 | "name": "cooling", | ||
221 | "state": "active", | 221 | "state": "active", | ||
222 | "vocabulary_id": null | 222 | "vocabulary_id": null | ||
223 | }, | 223 | }, | ||
224 | { | 224 | { | ||
225 | "display_name": "electricity", | 225 | "display_name": "electricity", | ||
226 | "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", | 226 | "id": "0c58cb6b-5845-4112-9871-6adda7eaac59", | ||
227 | "name": "electricity", | 227 | "name": "electricity", | ||
228 | "state": "active", | 228 | "state": "active", | ||
229 | "vocabulary_id": null | 229 | "vocabulary_id": null | ||
230 | }, | 230 | }, | ||
231 | { | 231 | { | ||
232 | "display_name": "power quality", | 232 | "display_name": "power quality", | ||
233 | "id": "f75b4ff7-2ba6-44ba-8468-c1e9c3ba08e4", | 233 | "id": "f75b4ff7-2ba6-44ba-8468-c1e9c3ba08e4", | ||
234 | "name": "power quality", | 234 | "name": "power quality", | ||
235 | "state": "active", | 235 | "state": "active", | ||
236 | "vocabulary_id": null | 236 | "vocabulary_id": null | ||
237 | } | 237 | } | ||
238 | ], | 238 | ], | ||
239 | "temporal_resolution": "1 second", | 239 | "temporal_resolution": "1 second", | ||
240 | "temporal_start": "2018-05-17", | 240 | "temporal_start": "2018-05-17", | ||
t | 241 | "title": "Kampusareena cooling machines consumption and power | t | 241 | "title": "Kampusareena cooling machines \u00eblectricity consumption |
242 | quality", | 242 | and power quality", | ||
243 | "type": "dataset", | 243 | "type": "dataset", | ||
244 | "url": "", | 244 | "url": "", | ||
245 | "version": "" | 245 | "version": "" | ||
246 | } | 246 | } |