Skip to content

Changes

View changes from to


On August 21, 2024 at 2:09:05 PM +0300, Gravatar hylli:
  • Updated description of Kampusareena Solar Power Plant Inverters (demo) from

    **Note**: This is a demo version of the dataset. ## Overview This dataset contains electrical measurements from the four inverters of the Kampusareena building's solar power plant. The plant has a maximum power production capacity of 57 kW, with the power output directed to the top floor ventilation machine room. ## Solar Power Plant Specifications - **Total Capacity**: 57 kW - **Location**: Kampusareena building, Tampere University ### Inverter Configuration The solar power plant consists of four inverters distributed across three walls: 1. West Wall: - 1x SMA STP8000TL (8 kW) 2. Southwest Wall: - 1x SMA STP15000TL (15 kW) 3. Southeast Wall: - 2x SMA STP17000TL (2 x 17 kW) ## Measurements The dataset includes various electrical parameters, such as: - Frequency - Current - Voltage - Power - Energy ### Data Collection Frequency - Most data: 1-second interval - Static inverter data: Once per day or upon collector restart (marked as "read once" in the available measurements list) ## Data Structure in DELI Platform **Database**: `root.kampusareena` **Devices**: - `root.kampusareena.Electricity.SolarPVPlant.WestWall.Inverter01` - `root.kampusareena.Electricity.SolarPVPlant.SouthEastWall.Inverter02` - `root.kampusareena.Electricity.SolarPVPlant.SouthEastWall.Inverter03` - `root.kampusareena.Electricity.SolarPVPlant.SouthWestWall.Inverter04` For a detailed list of available measurements, please refer to the attached "available measurements" file. ## Important Notes - **Data Quality Issue**: Data collected before 2018-08-08 may contain erroneous values (large negative numbers like -2147483648). This occurred when the collection system misinterpreted the "no data" signal from non-operating inverters, often during nighttime. ## Additional Resources - [ProCem Project Information](https://ckan.energydata.rd.tuni.fi/organization/about/procem-demo): Details on measurement storage and usage - [Kampusareena Group](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena): General information about the building ## Data Access and Usage To access and utilize this dataset: 1. Review the attached "available measurements" list for specific measurement paths. 2. Follow the data access procedures outlined in the ProCem project documentation. 3. Use the appropriate database and device paths as specified in the "Data Structure" section above when querying data.
    to
    **Note**: This is a demo version of the dataset. ## Overview This dataset contains electrical measurements from the four inverters of the Kampusareena building's solar power plant. The plant has a maximum power production capacity of 57 kW, with the power output directed to the top floor ventilation machine room. ## Solar Power Plant Specifications - **Total Capacity**: 57 kW - **Location**: Kampusareena building, Tampere University ### Inverter Configuration The solar power plant consists of four inverters distributed across three walls: 1. West Wall: 1x SMA STP8000TL (8 kW) 2. Southwest Wall: 1x SMA STP15000TL (15 kW) 3. Southeast Wall: 2x SMA STP17000TL (2 x 17 kW) ## Measurements The dataset includes various electrical parameters, such as: - Frequency - Current - Voltage - Power - Energy ### Data Collection Frequency - Most data: 1-second interval - Static inverter data: Once per day or upon collector restart (marked as "read once" in the available measurements list) ## Data Structure in DELI Platform **Database**: `root.kampusareena` **Devices**: - `root.kampusareena.Electricity.SolarPVPlant.WestWall.Inverter01` - `root.kampusareena.Electricity.SolarPVPlant.SouthEastWall.Inverter02` - `root.kampusareena.Electricity.SolarPVPlant.SouthEastWall.Inverter03` - `root.kampusareena.Electricity.SolarPVPlant.SouthWestWall.Inverter04` For a detailed list of available measurements, please refer to the attached "available measurements" file. ## Important Notes - **Data Quality Issue**: Data collected before 2018-08-08 may contain erroneous values (large negative numbers like -2147483648). This occurred when the collection system misinterpreted the "no data" signal from non-operating inverters, often during nighttime. ## Additional Resources - [ProCem Project Information](https://ckan.energydata.rd.tuni.fi/organization/about/procem-demo): Details on measurement storage and usage - [Kampusareena Group](https://ckan.energydata.rd.tuni.fi/group/about/kampusareena): General information about the building ## Data Access and Usage To access and utilize this dataset: 1. Review the attached "available measurements" list for specific measurement paths. 2. Follow the data access procedures outlined in the ProCem project documentation. 3. Use the appropriate database and device paths as specified in the "Data Structure" section above when querying data.


  • Changed value of field datastore_active to True in resource available measurements in Kampusareena Solar Power Plant Inverters (demo)